FMX 400/FMX 700 SERIES USER MANUAL

21

10-1     Introduction to Radiometry

The basic reason for employing image processing programs when analyzing IR 

images is to have a fast and comprehensive means to determine the information 

content of an image in numerical terms. Radiometry is considered the base from 

which to conduct this analysis. 

Typically, converting the gray scale values to values of temperatures requires 

either a calibration of individual cameras or field calibration data. The method 

for calibrating images provided in this program is camera dependent because 

temperature calibration data is collected through an advanced calibration 

process at the factory and installed within the software program. 

IR Flash Pro looks for a very specific file in its structure and mates that with the 

camera serial number automatically read by the program. If this software cannot 

match the camera to the calibration file, the user cannot perform temperature 

analysis on the data. Contact customer service if there is an issue.

IF YOUR PACKAGE INCLUDES ADDITIONAL LENSES A SEPARATE CALIBRATION 

IS REQUIRED FOR EACH LENS. CONTACT CUSTOMER SERVICE IS THERE IS AN 

ISSUE.

10-2    Radiometry Correction 

The accuracy of temperature conversion is also dependent on the physics of the 

scene. These physical properties include humidity, emissivity and reflection of 

the target, the transmission in the intervening atmosphere, and the background/

foreground temperature within the scene. 

Information for an image is stored in the Project Information/Zones area and can 

be retrieved by clicking the drop-down tab next to “Image”. ROI data is stored 

under “Zones”. 

The dialog box shown below allows users to offset potential 

errors by typing precise values into the input field next to the property:

Use the input fields 

to enter information 

and numerical data.

Users can include data 

in reports. To toggle 

data on/off click  the 

squares. Boxes are 

green when selected. 

IMAGE DATA, I.E. INFORMATION FOR THE ENTIRE IMAGE, IS SEPARATE FROM 

REGION  OF  INTEREST  DATA,  INFORMATION  STORED  IN  THE  ROI  CREATED 

BY  THE  USER.  VISIT  THE  APPROPRIATE  DROP-DOWN  TAB  TO  INCLUDE 

PREFERRED INFORMATION IN THE REPORT.

10.

Radiometry

Summary of Contents for FMX 400 Series

Page 1: ...UNIT ON IMPORTANT SAFETY INFORMATION INSIDE 2105 W Cardinal Dr Beaumont TX 77705 ICI cameras fall under US Federal Law and Export Control For more information contact us 409 861 0788 sales infraredcam...

Page 2: ...FMX 400 FMX 700 SERIES USER MANUAL 2 Revision History 11 2022 001 Document created...

Page 3: ...al Specifications 11 Structure 13 5 1 Appearance and Definitions of Housing Interface 13 Package Includes 14 Quick Start Instructions 15 7 1 Setup 15 7 2 Software Installation 17 Operation Instruction...

Page 4: ...ot showing camera s lagging or software crashing 25 11 2 Thermal imager shuts off unexpectedly 25 11 3 No thermal image 25 11 4 Camera out of focus 25 11 5 Unclear or dark visible images 26 11 6 Tempe...

Page 5: ...ten permission of Infrared Cameras Inc The documentation must not in whole or part be copied photocopied reproduced translated or transmitted to any electronic medium or machine readable form without...

Page 6: ...ent The crossed out wheeled bin symbol indicates that waste electrical and electronic equipment should not be discarded together with unseparated household waste but must be collected separately All l...

Page 7: ...of energy emitted from the first 1 1000th of an inch of a subject Environment of use industrial and petrochemical buildings electrical plants security rooms science labs animal reserves as well as en...

Page 8: ...FMX 400 FMX 700 SERIES USER MANUAL 8 2 9 Training To read about infrared training visit https infraredtraininginstitute com...

Page 9: ...er cord and do not place the device where the power cord can be easily touched Do not get water or salt water on the device or permit the device to get wet Damage to the device may occur Remove any wa...

Page 10: ...ED WITH THEIR CORRECT COVERS HATCHES OR CAPS THIS INCLUDES THE COMPARTMENTS FOR DATA STORAGE BATTERIES IF APPLICABLE AND CONNECTORS Do not put the product into a fire It is recommended to calibrate th...

Page 11: ...5 to 85 C 49 F to 185 F Detector Array UFPA VOx Pixel Pitch 17 m FOV 47 x 35 6 Focus Electronic Measurement Distance Lens dependent Spectral Band 8 m to 14 m Thermal Sensitivity NETD 40 mK 0 04 C at 3...

Page 12: ...12 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE FMX 400 P FMX 700 P Video Raw Emissivity Correction 0 01 to 1 0 IP Rating IP54 Internal non uniformit...

Page 13: ...00 SERIES USER MANUAL 13 5 1 Appearance and Definitions of Housing Interface 5 Structure 1 Germanium Lens 2 LED Indicator Light 3 Power Interface 4 Data Interface 5 RJ 45 Internet access 6 Reset Butto...

Page 14: ...00 SERIES USER MANUAL 14 6 Package Includes ENSURE ALL SYSTEM EQUIPMENT AND COMPONENT ITEMS ARE PRESENT BEFORE BEGINNING INSTALLATION Coaxial Cable Power Adapter Ethernet Cable FMX Series device Softw...

Page 15: ...ctions MAKE SURE TRIPODS DO NOT BLOCK THE DIRECT PATH OF PERSON S TO BE IMAGED TO ENSURE THE EQUIPMENT WILL NOT BE MOVED OR KNOCKED DOWN USING A DIVIDING BARRIER WILL HELP KEEP TRIPODS SEPARATE FROM T...

Page 16: ...end of coaxial cable B C Plug Ethernet cable into the Ethernet port of the FMX Series device Plug the other end of the Ethernet cable into the Ethernet port of the computer ENSURE THE CAMERA LENS AND...

Page 17: ...T 10 MINUTES FOR THE DEVICE TO ACCLIMATE THIS WILL PROVIDE THE MOST ACCURATE TEMPERATURE MEASUREMENTS 7 2 Software Installation A B Install IR Flash software using the software USB drive Refer to the...

Page 18: ...d to set a gateway as this is a direct connection from the computer to the cameras with no router Be sure the static IP address is set by doing the following 1 Click on Windows icon 2 Click on Setting...

Page 19: ...h Pro web page under the Downloads section or at this address https infraredcameras com ir flash pro manual Processor Intel i5 Quad core or above RAM 4 GB or above OS Windows 8 8 1 10 Hard Drive 256 G...

Page 20: ...ean replace the cloth and repeat the wiping process 9 2 Disinfecting the Camera Surface Do not use corrosive cleaning solutions on the optical glass components It is recommended to disinfect the camer...

Page 21: ...tomer service if there is an issue IF YOUR PACKAGE INCLUDES ADDITIONAL LENSES A SEPARATE CALIBRATION IS REQUIRED FOR EACH LENS CONTACT CUSTOMER SERVICE IS THERE IS AN ISSUE 10 2 Radiometry Correction...

Page 22: ...is To set the emissivity enter a value from 0 01 to 1 0 in the input box The accompanying table gives the typical emissivity of important materials Material Emissivity Water 96 Stainless steel 14 Alum...

Page 23: ...over water there may be no perceived thermal difference between the horizon and the water i e the horizon can seem to disappear Users can change their angle by changing where they stand or by attachin...

Page 24: ...the screen plots image information in the form of a histogram or a 3D rendering It also allows users to visualize the temperature data over time for any all ROIs placed on the image the last image bel...

Page 25: ...t mask of 255 255 255 0 Restart computer Verify that correct software is installed Uninstall reinstall software running as administrator Verify that firewall is not blocking software Try newer or diff...

Page 26: ...incorrect Turn off the device then turn it back on Ensure the device has sufficiently acclimated to the environment before taking measurements Device is at proper height Ensure device is in focus Adj...

Page 27: ...engineers scientists inspectors and operators in space power companies medical pulp and paper food industry research and development and various process industries You can see our products and servic...

Reviews: