background image

MONOLITE

 

 

3 TECHNICAL 

SPECIFICATIONS 

3.1 

MONOLITE 45 GT – 350 GT 

Characteristics

Effic. 100%

(stars)

NG max flow

rate G20

NG max flow

rate G30

NG max flow

rate G31

Max flow rate

of flues

kW

kcal/h

kW

kcal/h

kW

kcal/h

%

%

%

m³/h

kg/h

kg/h

kg/h

Medium 

Temp.

70°C

Temp. 

flow/return

50/30°C

(Efficienty Dir.

92/42/CEE)

MONOLITE 45 GT

52,0

45.000

57,0

49.200

53,0

45.800

98,3

107,5

****

5,64

4,18

4,14

84,04

MONOLITE 70 GT

81,0

70.000

88

76.500

82,0

71.200

98,3

107,5

****

8,76

6,50

6,43

130,52

MONOLITE 95 GT

110,0

95.000

120

103.800 112,0

96.600

98,3

107,5

****

11,89

8,82

8,73

177,16

MONOLITE 125 GT

145,0 125.000

158

136.700 147,0 127.200

98,3

107,5

****

15,65

11,62

11,49

233,19

MONOLITE 160 GT

186,0 160.000

203

175.000 189,0 162.800

98,3

107,5

****

20,03

14,87

14,71

298,45

MONOLITE 210 GT

244,0 210.000

266

229.600 248,0 213.600

98,3

107,5

****

26,28

19,51

19,30

391,57

MONOLITE 270 GT

313,0 270.000

343

295.300 319,0 274.700

98,3

107,5

****

33,80

25,09

24,81

503,62

MONOLITE 350 GT

406,0 350.000

445

382.800 414,0 356.100

98,3

107,5

-

43,82

32,52

32,17

652,92

Efficiency 100%

(N.C.V.)

Temp. flow/return

50/30°C

Medium Temp.

 70°C

Heat output

Heat input

 

Characteristics

Effic. 30%

(stars)

NG min flow

rate G20

NG min flow

rate G30

NG min flow

rate G31

Min flow rate

of flues

kW

kcal/h

kW

kcal/h

kW

kcal/h

%

%

%

m³/h

kg/h

kg/h

kg/h

Medium 

Temp.

70°C

Temp. 

flow/return

50/30°C

(Efficienty 

Dir.

92/42/CEE)

MONOLITE 45 GT

17

15.000

19

16.599

17

15.228

98,5

109

****

1,87

1,39

1,38

27,92

MONOLITE 70 GT

26

23.000

30

25.452

27

23.350

98,5

109

****

2,87

2,13

2,11

42,81

MONOLITE 95 GT

37

32.000

41

35.411

37

32.487

98,5

109

****

4,00

2,97

2,93

59,56

MONOLITE 125 GT

48

42.000

54

46.477

49

42.640

98,5

109

****

5,25

3,89

3,85

78,18

MONOLITE 160 GT

61

53.000

68

58.650

62

53.807

98,5

109

****

6,62

4,91

4,86

98,65

MONOLITE 210 GT

81

70.000

90

77.462

82

71.066

98,5

109

****

8,74

6,49

6,42

130,29

MONOLITE 270 GT

104

90.000

116

99.594

106

91.371

98,5

109

****

11,24

8,34

8,25

167,52

MONOLITE 350 GT

136

117.000

151

129.472

138

118.782

98,5

109

-

14,62

10,85

10,73

217,77

Minimum

output

Minimum

input

Efficiency at 30%

(N.C.V.)

Medium Temp.

70°C

Temp. flow/return

50/30°C

 

Characteristics

Pressure losses

flue gas side

Chimney

available head

Noise

level

CO

emissions

Nox

emissions

Heat losses through

 the chimney

Heat losses through

the casing

Heat losses with

burner off

Flue gas temp. at boiler

output and air at 20 deg. C

Condense

production

Press. losses

water side

Design

Pressure

Total

capacity

Boiler

weight

Electric

supply

Frequency

Insulation

class

Electric

power

mbar

mbar

dB(A) mg/kWh

mg/kWh

%

%

%

°C

kg/h

mbar

bar

l

kg

Volt ~

Hz

IP

W

For condensing

Temp. flow/return

50/30°C

For condensing

Temp. flow/return

50/30°C

For condensing

Temp. flow/return

50/30°C

GAS

For condensing

Temp. flow/return

50/30°C

Temp. 

flow/return

50/30°C

 (

Δ

T=12K)

MONOLITE 45 GT

0,6

0,5

62,0

0

45

1,50

0,30

0,10

50

6,68

3,0

5

160

200

230

50

IP X0D

150

MONOLITE 70 GT

0,8

0,2

62,5

0

58

1,50

0,30

0,10

50

10,38

8

5

150

220

230

50

IP X0D

150

MONOLITE 95 GT

1,0

0,5

62,5

0

55

1,50

0,30

0,10

50

14,09

12

5

210

280

230

50

IP X0D

150

MONOLITE 125 GT

1,1

0,5

63,0

0

65

1,50

0,30

0,10

50

18,55

22

5

200

320

230

50

IP X0D

150

MONOLITE 160 GT

1,5

0,5

65,0

0

52

1,50

0,30

0,10

50

23,74

12

5

308

520

230

50

IP X0D

300

MONOLITE 210 GT

2,0

0,5

66,0

0

58

1,50

0,30

0,10

50

31,14

22

5

285

590

230

50

IP X0D

300

MONOLITE 270 GT

2,1

0,5

68,0

0

60

1,50

0,30

0,10

50

40,05

16

5

340

680

230

50

IP X0D

300

MONOLITE 350 GT

2,3

0,5

68,0

0

65

1,50

0,30

0,10

50

51,93

11

5

392

1030

230

50

IP X0D

300

 

Mod. 45 GT – 125 GT 

 

Summary of Contents for MONOLITE JB Series

Page 1: ...TECHNICAL MANUAL MONOLITE GT CONDENSING BOILER WITH PREMIX BURNER MONOLITE JB CONDENSING BOILER WITHOUT BURNER LOW NOx STEEL CONDENSING BOILERS...

Page 2: ......

Page 3: ...RE MOD 45 GT 125 GT 13 4 8 INVERTING THE DOOR APERTURE mod 160 GT JB 350 GT 670 JB 13 4 9 PRESSURISED BOILER CONNECTION 14 4 10 WIRING DIAGRAM 14 5 FITTING THE BOILER CASING 15 5 1 BOILER BODY INSULAT...

Page 4: ...without inversion limits as much as possible the formation of Nitrogen Oxides NOx that form when the flame remains at high temperature in the combustion chamber for long periods The MONOLITE series b...

Page 5: ...itioned on the control panel should be checked for efficiency The guarantee shall be valid only upon compliance with the instruction given in this manual Our boilers have been built and tested in obse...

Page 6: ...5 3 89 3 85 78 18 MONOLITE 160 GT 61 53 000 68 58 650 62 53 807 98 5 109 6 62 4 91 4 86 98 65 MONOLITE 210 GT 81 70 000 90 77 462 82 71 066 98 5 109 8 74 6 49 6 42 130 29 MONOLITE 270 GT 104 90 000 11...

Page 7: ...N10 mm mm mm mm mm mm mm mm mm mm mm DN in DN in DN in DN in DN in DN inDN inDN in DN in DN in MONOLITE 45 GT 1267 1210 670 595 350 322 715 150 150 50 50 1 1 1 2 3 4 1 2 50 3 4 MONOLITE 70 GT 1267 12...

Page 8: ...4 91 4 86 98 65 MONOLITE 210 JB 81 70 000 90 77 462 82 71 066 98 5 109 0 8 74 6 49 6 42 130 29 MONOLITE 270 JB 104 90 000 116 99 594 106 91 371 98 5 109 0 11 24 8 34 8 25 167 52 MONOLITE 350 JB 136 1...

Page 9: ...0 JB KEY N1 Boiler flow N2 Medium temperature return N3 Fitting for Instruments N4 System filling drainage N5 Safety valve s fitting N6 Bulbs wells N7 Boiler condensation drain N8 Inspection well N9 L...

Page 10: ...P8 b c N1 N2 N3 N4 N5 N6 N7 N8 N9 mm mm mm mm mm mm mm mm mm mm mm DN in DN in DN in DN in DN in DN inDN inDN in DN in MONOLITE 30 JB 990 881 670 318 350 322 200 250 150 150 50 50 1 1 1 2 3 4 1 2 50 M...

Page 11: ...as temperatures produced by MONOLITE boilers are considerably lower than in the case of non condensing boilers and have therefore very high relative humidity For these reasons the chim ney must be com...

Page 12: ...MONOLITE 10 4 3 1 SEALED HOT WATER HEATING SYSTEM WITH EXPANSION VESSEL Mod 45 125 Mod 160 270...

Page 13: ...ulation thermostat n 1 19 Regulation thermostat n 2 20 Manual reset safety thermostat 21 Shock absorbing pipe 22 Safety valve n 1 the 2 nd has a heating capacity above 580 kW 23 Fuel shut off valve 24...

Page 14: ...l thermostats TR1 TR2 have an operating range from 0 to 90 and can be set by the user by means of the front dial Safety limit thermostats TS has a fixed setting of 100 0 6 C and can be manually reset...

Page 15: ...NVERTING THE DOOR APERTURE mod 160 GT JB 350 GT 670 JB If the door is to be opened to the opposite side act as follows 1 Switch the outside nut or bush of one hinge with the diametrically opposite clo...

Page 16: ...nd regulations g check that all gas connections are perfectly gas tight h check that the boiler room ventilation openings are dimensioned to guarantee an air flow as foreseen by applicable regulations...

Page 17: ...r control panel connection cables passing through the aperture for the wiring harness please refer to the control panel diagram and to the standard plugs connection kit Unwind the thermostat capillari...

Page 18: ...harness please refer to the control panel diagram and to the standard plugs connection kit Unwind the thermostat capillaries fit the control panel to the side fastening with the screw then insert the...

Page 19: ...e existing opening for the wiring harness please refer to the control panel diagram and to the standard plugs connection kit Unwind the thermostat capillaries attach the control panel 3 to the side wi...

Page 20: ...osed to the flame and reducing considerably the boiler life Furring concentrates where the boiler wall temperature is higher and the best defence against this phenomenon is a boiler design that elimin...

Page 21: ...er WARNING during long stoppages in winter and in order to avoid frost damage drain both the sanitary wa ter and the heating system water drainage of the latter can be avoided by adding antifreeze Boi...

Page 22: ...arted in via G Pascoli 38 37059 Campagnola di Zevio VR Italia DECLARE THAT BOILERS MONOLITE 45 GT 70 GT 95 GT 125 GT with burner MONOLITE 160 GT 210 GT 270 GT 350 GT body only MONOLITE JB comply with...

Page 23: ......

Page 24: ...scoli 38 Zevio fraz Campagnola VERONA ITALIA Tel 045 8738511 Fax 045 8731148 info icicaldaie com www icicaldaie com The data reported are indicative only and are not binding Our company reserves the r...

Reviews: