Installation
18
INSULATING CASING ASSEMBLY
To fit the insulating casing proceed as follows:
–
wrap the thermally insulating mats around the Boiler body and lock them with the supplied springs (1)
–
prepare all the slats (2) inserting the locking plugs (3) in the corners of each one of them, as shown in the figure below
1
2
3
–
open the control panel (4) and fasten it to the panel supporting slat (5) using the supplied screws and nuts
–
fasten the front (6) and rear (9) pillars to the base and to the plates (6) using the supplied screws and nuts
–
insert the slats (2) on the lateral side
m
IMPORTANT
The panel supporting slat (5) must be the ninth one on the side featuring the control panel.
9
5
4
7
6
6
8
2
2
–
fasten the two cross beams (10) to the plates (6), insert the upper slats (11), fasten the end profiles (12) using the supplied self-
threading screws.
10
10
12
12
11
Cooke Industries - Phone: +64 9 579 2185 Email: [email protected] Web: www.cookeindustries.co.nz