6 Troubleshooting and Warning Lights
Commonfault
Reason
Solution
Remarks
iCleaner-200D
doesn't work
Weak pumping
iCleaner-200D is
turning to one side
when it moves
iCleaner-200D
will not climbs
wall
iCleaner-200D
will not sink to the
bottom of the pool
Dirt is coming
through the
guide vane.
The socket is
not plugged in
Connection is wrong
Impeller is
jammed or dirty
Impeller is damaged
Filter Bag is full
Drive Belt is loosen
or broken at one side
The Filter Bag is full
The Filter Bag is full
Drive Belt is
loosen or broken
Sponge wheel wear
axis sleeves wear
The sponge wheel
don't soak enough
It has air inside
the machine
Belt of Filter Bag is
loosen or broken.
Dirt is too fine for
the filter bag
Plug in the power lead
Check the connection
clean the Impeller
Replace the impeller
Clean the Filter Bag
replace the drive Belt
Clean Filter Bag
Clean Filter Bag
Replace the Drive Belt
Replace the Sponge Wheel
replace axis sleeves
Wobble iCleaner-200D and
make sure air released
Replace the broken filter bag
Please turn
off the power
before you
perform any
maintenance
on the
iCleaner-200D
Note: The Power Box MUST BE DISCONNECTED from the power supply prior to
conducting any maintenance on the iCleaner-200D. Contact your local distributor, or place of
purchase for problems not covered in the Troubling Shooting Guide.
- 17 -
you must hold cleaner
in water and make sure
sponge wheel soak enough,
normal time is
about 5 -15 minutes