49
Note:
The discharging current is always set to be half of the coming charging current whose
upper limit is 1000 mA (see Table 2). Therefore user is recommended to carefully select the
discharging current so that the charging current afterward will not be too high.
Table 2. DISCHARGE MODE Current
User-selected Discharging
current
100 mA
250 mA
350 mA
500 mA
Thereafter Charging current
200 mA
500 mA
700 mA
1000 mA
Finally batteries will be fully charged in discharge mode and “Full” will be displayed. If user
presses DISPLAY key at this time, "charge" icon instead of "discharge" icon will be displayed.
REFRESH MODE
Old rechargeable batteries and those have not been used for a long time require refreshing.
This process will recover the optimum capacity of the rechargeable batteries. By pressing the
MODE key within 8 seconds after inserting the rechargeable batteries, the Refresh mode can be
selected.