Error Codes and Corrective Actions
The Ice Cream Machines may malfunction due to incorrect operation procedure or a trivial cause other than
machine defect or failure. If the following corrective actions fail to correct the problem, or the error code is
not presented below, or the same error persists, contact the nearest After Service Center.
※ Before contacting the After Service Center, turn power off, wait for five minutes, then turn power on
and start the machine again.
Error code
Possible Cause
Corrective Action
Release
Action
Er00
Mix Out
Fall short of row material Refill row material in the
storage container
Auto release
Stop
Er01
Hop. Sensor Op.
Cooler sensor OPEN
Sensor failure(contact A/S Center) Auto release
Stop
Er02
Hop. Sensor St.
Cooler sensor SHORT
Sensor failure(contact A/S Center) Auto release
Stop
Er03
Cyl. Sensor Op.
Cooler sensor OPEN
Sensor failure(contact A/S Center) Auto release
Stop
Er04
Cyl. Sensor St.
Cooler sensor SHORT
Sensor failure(contact A/S Center) Auto release
Stop
Er07
EOCR
Motor over current
detected
Melt the ice cream and
restart the machine
Reset
Reset operation
Er08
High Pressure
Over voltage detected
Clean the filter unit,
check exhaust air line
Auto release
Stop
Er09
noLA
Product immature yet
Refrigerant problem(contact A/S Center) Auto release operation
Er12
Draw Switch Er.
Discharge lever ERROR Lift the discharge lever
Auto release operation
Er13
Condensor OH
Abnormal temperature of
condenser
Check the vent for clogging.
Auto release operation
Er14
Motor Belt Er.
Defective drive shaft
Melt the ice cream and
restart the machine
Reset
Reset operation
Er15
EEPROM Error
EEPROM fault
PCB fault(contact A/S Center)
Reset
operation
Er17
Heating Error
Defective sterilization
function
Replace the ice cream row
material and clean the machine
Other
operation
operation
Er18
Cover Error
Defective dasher cover Mount the dasher cover
at correct position
Auto release
Stop
Er19
Eva. Sensor Op.
Eva. Sensor OPEN
Sensor failure(contact A/S Center) Auto release operation
Er20
Eva. Sensor St.
Eva. Sensor SHORT
Sensor failure(contact A/S Center) Auto release operation
Er21
Motor Power Er.
Failed to detect electric
motor current
Machine failure
(contact A/S Center)
After reset
release
Reset operation
Er50
Power IC Er.
Power IC ERROR
Sensor failure (contact A/S Center) Auto release
Stop
Er51
Caburetor Er.
Carburetor sensor error Sensor failure (contact A/S Center) Auto release
Stop
Er52
Invertor Comm.
Inverter communication
error
Sensor failure (contact A/S Center) Auto release
Stop
Er53
Invertor OC
Inverter over current
Sensor failure (contact A/S Center) Auto release
Stop
Er54
Invertor OE
Inverter over voltage
Sensor failure (contact A/S Center) Auto release
Stop
Er55
Invertor OE
Inverter over heat
Sensor failure (contact A/S Center) Auto release
Stop
Er56
Invertor LU
Inverter under voltage
Sensor failure (contact A/S Center) Auto release
Stop
Er57
Invertor TH
Erroneous detection of
temperature senso
Sensor failure (contact A/S Center) Auto release
Stop
Er58
Invertor COM
Communication failure
detected
Sensor failure (contact A/S Center) Auto release
Stop
Er59
Invertor OL
Mean overvoltage
detected
Sensor failure (contact A/S Center) Auto release
Stop
Er60
Invertor OT
Max. output protection
Sensor failure (contact A/S Center) Auto release
Stop
Er61
Control Comm.
Control pcb
communication error
PCB fault(contact A/S Center)
Auto release
Stop
Summary of Contents for ISI-161TH
Page 33: ...33 Wiring diagram ...
Page 34: ...34 Refrigeration circuit diagram Sterilization operation Normal operation ...
Page 39: ...39 Part list ...
Page 40: ...40 Part list ...
Page 41: ...41 Part list ...
Page 42: ...42 Part list ...
Page 43: ...43 Part list ...
Page 44: ...44 Part list ...
Page 46: ...46 MEMO ...
Page 47: ...47 MEMO ...
Page 48: ...3240385 01 Online Internet Service http www icetro com ...