ICE TECH SS / SP Technical Service
Manual
23
4) Prepare a solution of 50% phosphoric acid in distilled water.
5) Distribute solution through condenser. (Solution is more effective at 35°-40°C).
WARNING!
DO NOT USE HYDROCHLORIC ACID
Air Condenser
1) Disconnect machine.
2) Close water faucet.
3) Clean condenser using a vacuum cleaner, soft brush and/or low-pressure air.
Evaporator/Water Trough
1) Disconnect machine.
2) Remove drain plug situated in lower bearing.
3) Use a container to collect water.Allow water to flow for 2 to 3 minutes.
4) Close water entrance and replace plug.Prepare a solution of 50% phosphoric acid in distilled
water.
Do not use hydrochloric acid.
5) SPowly pour solution into water deposit. (Solution is more effective at 35°-40°C).
6) Let solution stand for 20 minutes.
7) Remove lower plug and empty deposit.
8) Replace plug.
9) Fill container with solution to maximum capacity.
10) Connect machine and wait for unit to automatically shut off when remaining liquid drains.
WARNING:** Discard ice produced during cleaning procedure.
11) Disconnect machine.
12) Remove plug.
13) Open faucet and let water run for 2 to 3 minutes.
14) Close faucet, place plug, open faucet and connect the machine.
**At this point sanitary cleaning starts
15) SPowly add bleach to water deposit for at least 5 minutes.