GB
19
F. FINAL CHECK LIST
1.
Is the unit in a room where ambient temperatures are
within a minimum of 10°C (50°F) even in winter
months?
2.
Is there at least a 15 cm (6”) clearance arround the
unit for proper air circulation?
3.
Is the unit level? (IMPORTANT)
4.
Have all the electrical and plumbing connections
been made, and is the water supply shut-off valve
open?
5.
Has the voltage been tested and checked against the
data plate raiting?
6.
Has the water supply pressure been checked to
ensure a water pressure of at least 1 bar (14 psi).
7.
Have the bolts holding the compressor down been
checked to ensure that the compressor is snugly fit-
ted onto the mounting pads?
8.
Check all refrigerant lines and conduit lines to guard
against vibrations and possible failure.
9.
Have the bin liner and cabinet been wiped clean?
10. Has the owner/user been given the User Manual and
been instructed on the importance of periodic main-
tenance checks?
11. Has the Manufacturer’s registration card been filled in
properly? Check for correct model and serial nuber
against the serial plate and mail the registration card
to the factory.
12. Has the owner been given the name and the phone
number of the authorized Service Agency serving
him?
G. INSTALLATION PRACTICE
WARNING This icemaker is not designed for outdoor installation and will not function in ambient tempera-
tures below 10°C (50°F) or above 40°C (100°F).
This icemaker will malfunction with water temperatures below 5°C (40°F) or above 40°C (100°F).
1. Hand shut-off valve
2. Water filter
3. Water supply line (flexible hose)
4. 3/4” GAS male fitting
5. Vented drain
6. Open trapped vented drain
7. Drain fitting
8. Main switch
9. Power line
Summary of Contents for N21
Page 16: ...GB 30 ELECTRIC DIAGRAM N21...