HOW TO USE THE RESET/WASH BUTTON
a.
Pressing the button n. 6
whether
momentarily or pressing and holding)
when the machine is in alarm mode, the
machine resets and returns to normal
operating mode.
b.
Pressing the button n. 6
for less than
6-8 sec. when the machine is not in alarm
mode, nothing will happen..
c1. Pressing and holding the button for more
than 6-8 sec when the machine is not in
alarm mode (in effect, when freezing, or
when the storage bin is full and freezing is
prevented), the machine sets itself for the
wash/rinse program by switching to a
stand-by configuration: from this moment
until the program is completed, the yellow
led will continue to blink (slowly at first,
about one beat per second) and all
functions are inhibited.
c2. Pressing the button n. 6
again acti-
vates the pump only (during “wash” the
led blinks steadily but more quickly, at
about three beats per second).
After 30 minutes, the machine automati-
cally goes into “rinse”;
The rinse can be started at any time
during the wash part of the program by
pressing the button momentarily.
c3. The rinse stage (during which the steady
blink of the yellow led becomes inter-
mittent) consists of the following opera-
tions:
– activation of drain solenoid valve and
pump for 30 sec. approx.
– deactivation of drain valve and pump.
– pause 1 minute
– activation of pump for 3 min.
– above sequence repeated another
seven times
– activation of drain valve for about 1 min.
N.B.: The pump operates continuously the
rinse stage. Rinse cycles cannot be
interrupted.
c4. At the end of the rinse stage, the machine
reverts automatically to the stand-by
configuration of c1).
d.
To quit the program, press n. 6
and
hold the button for at least 6-8 sec.
while the machine is in the stand-by
configuration (c1): the yellow led stops
blinking and the machine reverts to normal
operation.
IMPORTANT
To start making ice, wait until the machine has
finished the rinse program and is on stand-by:
– Machine idle, yellow led blinking.
To start the cycle, press and hold the
reset/wash button n. 6
.for more than 8 sec-
onds
1. Hi-pressure alarm
2. Power
3. Compressor
4. Bin full
5. Alarm
6. Reset/Cleaning
Summary of Contents for N 120 M
Page 2: ...2 I N120 200 300 500 M air water cooled SELF CLEANING PROCEDURE 32 28 29 30 30 30 30 31 ...
Page 15: ...15 I ...
Page 16: ...16 I ...
Page 17: ...17 I N120 200 300M and two thermostatic expan sion valves on model N500M ...
Page 18: ...18 I ...
Page 19: ...19 I ...
Page 20: ...20 I N500M N500M N500M ...
Page 23: ...23 I N500M N500M N500M ...
Page 24: ...24 I ...
Page 25: ...25 I cuber is a critically charged system ...
Page 26: ...26 I N120 200 300M WIRING DIAGRAM 220 V 50 Hz 1 ph ...
Page 27: ...27 I N500M WIRING DIAGRAM 380 V 50 Hz 3 ph ...
Page 28: ...28 I ...
Page 29: ...29 I ...
Page 34: ...34 I ...