11. Has the Manufacturer’s registration card
been filled in properly? Check for correct model
and serial number against the serial plate and
mail the registration card to the factory.
12. Has the owner been given the name and the
phone number of the authorized Service Agency
serving him?
G. INSTALLATION PRACTICE
1.
Hand shut-off valve
2.
Water filter
3.
Water supply line (flexible hose)
4.
3/4" male fitting
5.
Vented drain
6.
Open trapped vented drain
7.
Drain fitting
8.
Main switch
9.
Power line
WARNING. This icemaker is not designed for outdoor installation and will not function in
ambient temperatures below 10
°
C (50
°
F) or above 40
°
C (100
°
F).
This icemaker will malfunction with water temperatures below 5
°
C (40
°
F) or above 40
°
C
(100
°
F).