background image

 

 

26 

Rev. 2 

 

12000EVZ2 

 

Figure 18 

Summary of Contents for 1IQ0000EVZ2

Page 1: ...nstructions for safe and satisfactory installation and operation of this system Keep this manual for future reference Some information may not apply to all systems RELATED DRAWING DO NOT CHANGE WITHOUT AUTHORIZED PERSON APPROVAL FOR ZONE 2 ATEX IECEx UNITS ALL COMPONENTS ARE NON IGNITION SOURCE COMPONENTS AND DO NOT REQUIRE PURGE PROTECTION FROM ANY SOURCE Z2 ...

Page 2: ...e Standard Controller 11 Alarm Operation 13 Maintenance 14 Trouble Shooting 14 Schematic Wiring Diagrams 16 120V 220V 230V 16 400V 460V 480V 17 Specification Drawing 18 1000EVZ2 18 2000EVZ2 19 3000EVZ2 20 4000EVZ2 21 5000EVZ2 22 6000EVZ2 23 8000EVZ2 24 10000EVZ2 25 12000EVZ2 26 14000EVZ2 27 17000EVZ2 28 20000EVZ2 29 IQ1 2 3000EVZ2 Gasket and Cutout 30 IQ4 5 6000EVZ2 Gasket and Cutout 31 IQ8 10 120...

Page 3: ...t within the enclosure The three main thermal related systems that we employ are the closed loop cold air supply stream the heat rejection air stream and the vapor compression refrigeration system The closed loop cold air supply stream circulates cold air from the Ice Qube TMS to your electronics enclosure This air returns to the Ice Qube TMS bringing with it unwanted heat and humidity from inside...

Page 4: ...inimum of 24 hours before initial operation to ensure oil has returned to the compressor Operation before the 24 hour time may cause compressor damage and shorten the life of the system Operation before this 24 hour period will void all warranties Storage The storage space temperature should be in the range of 40 to 85 C 40 to 185 F in a non condensing environment CONDITIONS OF ACCEPTABILITY When ...

Page 5: ...nd warm air condenser blower will not operate if the room air temperature is below 80 F 27 C This is due to the fact that the programmable controller has a factory set point of 80 F 27 C The digital display on the face of the controller will be displaying room temperature If the display is indicating 80 F 27 C or warmer the Cool status LED will flash for 3 minutes before the compressor and the war...

Page 6: ... a seal against your enclosure and will maintain enclosure integrity See Figure 23 pg 31 Mechanical Installation Instruction Caution Protective safety clothing such as helmet gloves and steel toe shoes are recommended 1 Position the Ice Qube TMS so that the two mounting studs are in alignment with the top two 3 8 9 5mm holes in your enclosure surface 2 Slide the Ice Qube TMS mounting studs through...

Page 7: ...7 Rev 2 Figure 1 Enclosure Installation Figure 2 Push to Connect Fitting Ambient Side Enclosure Side ...

Page 8: ... Installation Checks 1 Check the air conditioner model label or specification for power requirements 2 Check the designated air conditioner power supply for adequate and proper electrical power requirements 3 Check that wire routing to the terminal box will not interfere with or become damaged by other components Electrical Installation 1 Check that the air conditioner designated power supply is d...

Page 9: ...9 Rev 2 Figure 4 Terminal Block Figure 5 Power Terminal Block ...

Page 10: ...n As soon as electrical power is supplied to the Ice Qube TMS the cool air stream blower will start to operate The blower will run continuously so that the controller can monitor the enclosure s internal temperature The enclosure temperature will be displayed on the face of the controller If the enclosure temperature is greater than the factory cooling set point of 80 F 27 C the Cool status LED wi...

Page 11: ...rating mode Note Pressing the 4 Exit button at any time while in the programming mode returns the controller to the normal operating mode Press 3 to continue programming The set temperature HI LED illuminates with the display indicating the Cooling On Set point The compressor will begin operation at this temperature and will remain operating until the enclosure temperature decreases approximately ...

Page 12: ...tons may be programmed as the code As the buttons are pressed the display will show the number of buttons that were pressed Note After pressing a button there will only be 5 seconds to press the next button If the next button is not pressed within the allotted time the system will default to no PIN code indicated by 0 on the display Once the sequence is entered the display will no longer flash and...

Page 13: ...The power is turned off The Alarm LED lights and the display flashes OFF indicating someone has manually interrupted power to the motors electrical circuits This alarm will be rest when the Por ON has been selected in the program menu Version 3 18 and later only 5 Optional Alarm Output Ice Qube offers an optional dry contact alarm output XO3 that provides both a normally open close on alarm and a ...

Page 14: ...se the system to fail The type of environment will determine the frequency of required maintenance Maintenance of the condensate management system will require access to the bottom of the air conditioner Removal of the neoprene tubing is necessary Replacement of the tubing is recommended if it appears to have internal build up or has become brittle Using a soft tube pipe cleaner insert into the dr...

Page 15: ...the compressor and condenser warm air stream blower operating Yes No Is the enclosure door closed tightly Yes No Are all of the gaskets in place Yes No Has the condenser warm air stream filter been cleaned or changed recently Yes No Is the system mounted level on the enclosure Yes No Is there adequate space within the enclosure for air flow Yes No Is there adequate space around the air conditioner...

Page 16: ...16 Rev 2 Schematic Wiring Diagrams 120V 220V 230V Figure 8 IQ351153 Rev A ...

Page 17: ...17 Rev 2 400V 460V 480V Figure 9 IQ351154 Rev A ...

Page 18: ...18 Specification Drawing 1000EVZ2 Figure 10 ...

Page 19: ...19 Rev 2 2000EVZ2 Figure 11 ...

Page 20: ...20 Rev 2 3000EVZ2 Figure 12 ...

Page 21: ...21 Rev 2 4000EVZ2 Figure 13 ...

Page 22: ...22 Rev 2 5000EVZ2 Figure 14 ...

Page 23: ...23 Rev 2 6000EVZ2 Figure 15 ...

Page 24: ...24 Rev 2 8000EVZ2 Figure 16 ...

Page 25: ...25 Rev 2 10000EVZ2 Figure 17 ...

Page 26: ...26 Rev 2 12000EVZ2 Figure 18 ...

Page 27: ...27 Rev 2 14000EVZ2 Figure 19 ...

Page 28: ...28 Rev 2 17000EVZ2 Figure 20 ...

Page 29: ...29 Rev 2 20000EVZ2 Figure 21 ...

Page 30: ...30 Rev 2 IQ1 2 3000EVZ2 Gasket and Cutout Same Gasket and Cutout for IQ1000EVZ2 IQ2000EVZ2 and IQ3000EVZ2 Figure 22 ...

Page 31: ...31 Rev 2 IQ4 5 6000EVZ2 Gasket and Cutout Same Gasket and Cutout for IQ4000EVZ2 IQ5000EVZ2 and IQ6000EVZ2 Figure 23 ...

Page 32: ...32 Rev 2 IQ8 10 12000EVZ2 Gasket and Cutout Same Gasket and Cutout for IQ8000EVZ2 IQ10000EVZ2 and IQ12000EVZ2 Figure 24 ...

Page 33: ...33 Rev 2 IQ14 17 20000EVZ2 Gasket and Cutout Same Gasket and Cutout for IQ14000EVZ2 IQ17000EVZ2 and IQ20000EVZ2 Figure 25 ...

Page 34: ...bility or any other theory of liability will be limited to the lesser of customer s actual damages or the price paid by customer to Ice Qube for the Products not including applicable taxes duties and freight charges that are the subject of customer s claim THE WARRANTY SET FORTH HEREIN IS STRICTLY LIMITED TO ITS TERMS AND IS IN LIEU OF ALL OTHER WARRANTIES GUARANTEES EXPRESS OR IMPLIED ARISING BY ...

Page 35: ...s be deemed to be non binding Such advice does not relieve customer from the obligation and customer accepts full responsibility to confirm for itself the suitability of the Products for their intended purpose s Remedies Customer s sole and exclusive remedy and Ice Qube s only obligation for breach of warranty hereunder shall be at Ice Qube s option in its sole discretion to i repair or replace th...

Page 36: ...36 Rev 2 Notes ...