ICE Series

 

 

 Installation Guidelines 

 

Page 2 

 

Installation Guidelines 

 

For proper operation of the Ice-O-Matic ice machine, the following installation guidelines must be followed.  Failure to 
do so may result in loss of production capacity, premature part failures, and may void all warranties. 
 
Reference the installation parameters prior to installing the machine: 
 

Ambient Operating Temperatures 

Minimum Operating Temperature:  50°F  (10°C) 
Maximum Operating Temperature 100°F  (38°C), 110°F  (43°C) on 50 Hz. Models. 

Note: Ice-O-Matic icemakers and dispensers are not approved for outdoor installation. 

 

Incoming Water Supply 

(See Electrical and Plumbing Diagrams for line sizing) 

Minimum incoming water temperature:  40°F  (4.5°C) 
Maximum incoming water temperature:  100°F  (38°C) 
Minimum incoming water pressure:   20 psi  (1.4 bar) (0,138MPa) 
Maximum incoming water pressure:  60 psi  (4.1 bar) (0.414 MPa) 

Note: If water pressure exceeds 60 psi (4.1 bar), a water pressure regulator must be installed. 
 
Drains  

All drain lines must be installed per local codes.  Flexible tubing is not recommended.  Route bin drain, purge drain and 
water condenser drain individually to a floor drain. 

 

The use of condensate pumps for draining water is not 

recommended by Ice-O-Matic.  Ice-O-Matic assumes no responsibility for improperly installed equipment. 

Note:

 

The purge drain fitting is plastic; DO NOT apply heat to the purge drain area; DO NOT overtighten.

 

 

Water Filtration 

A water filter system should be installed with the ice machine. 
 

Clearance Requirements 

Self-contained air cooled ice machines must have a minimum of 6 inches (15cm) of clearance at the rear, top, and 
sides of the ice machine for proper air circulation.  Exceptions such as Top Air Discharge machines will be listed in the 
machine specification sections. 
 

Stacking 

Ice-O-Matic does not endorse stacking ice machines. 
 

Dispenser Application 

A thermostatic bin control kit should be installed if the ICE Series ice machine is placed on a dispenser.  A bin top may 
or may not be required. 

(Exception is the CD400 Series Dispenser

 

Electrical Specifications 

Refer to the serial plate at the rear of the ice machine to make sure proper voltage and circuit breaker size have been 
supplied.  Make sure the machine is on a dedicated circuit.  European installations require that the electrical supply 
fixed wiring must be provided with a disconnect means having a separation of at least 3mm in all poles. The ice 
machines are provided without an electrical cord set and are designed and agency approved to be permanently 
connected. 
 

The 115 volt Undercounter series ice makers are supplied with an electrical cord, all other ice makers will 
need to be installed and wired per local electrical codes.  A GFI outlet is not approved. 
 
Caution: 

Electrical connection must be made or a cord installed by a qualified electrician or there is danger of an 

electrical fire.

 

 

Adjustments 

Level the machine within 1/8 inch in all directions. 
Check the bin control for proper adjustment. 
Check the water in the water trough for proper level. 
Check the ice bridge for proper thickness. 
Check the water regulating valve adjustment if water cooled.  

Summary of Contents for ICE 1506HR

Page 1: ...umber 9081264 01 Rev P Print Date 11 22 16 Installation Start Up and Maintenance Manual ICE SERIES CUBERS ICE0250 through ICE2100 Series ICEU150 ICEU220 and ICEU300 Undercounter Series ICE0320 ICE0520...

Page 2: ...the continuous improvement in both energy efficiency and productivity thereby delivering the best value in energy efficient ice machines money can buy For a detailed list of ENERGY STAR qualified Ice...

Page 3: ...Number and Serial Number Format Page 1 Installation Guidelines Page 2 Remote Condenser Guidelines Page 4 Electrical and Plumbing Requirements Page 6 How the Machine Works Page 15 Start Up Procedure Pa...

Page 4: ...er for carrier s inspection Visible Loss or Damage Any external evidence of loss or damage must be fully described and noted on your freight bill or express receipt and signed by the carrier s agent T...

Page 5: ...gerant This format is 14 characters long and begins with a date code followed by the Ice O Matic identifier and then a sequential number This is an entirely numerical serial number The serial number w...

Page 6: ...the ice machine Clearance Requirements Self contained air cooled ice machines must have a minimum of 6 inches 15cm of clearance at the rear top and sides of the ice machine for proper air circulation...

Page 7: ...condenser The water supply for the float can T off from the condenser line using 1 4 inch O D minimum tubing Make 2 coils of extra tubing so that the machine can be pulled away from the wall if servi...

Page 8: ...ding codes Usually the services of a licensed electrician are required Roof Attachment 1 Install and attach the remote condenser to the roof of the building using the methods and practices of construc...

Page 9: ...1B ICE0606R VRC1061B ICE0500R VRC1001B Limitations for remote machines that have the mixing valve mounted in the condenser Maximum Rise is 35 feet Maximum Drop is 15 feet Maximum equivalent run is 100...

Page 10: ...equirements ICEU150 220 225 and 226 ON OFF WASH Switch is located in the control box Remove the grill screws to access the control box Note The ICEU150 220 225 and 226 do not have a splash curtain The...

Page 11: ...bing Requirements ICEU300 and 305 Note The ICEU300 and ICEU305 do not have a splash curtain These models utilize a thermostatic bin control in place of a mechanical bin switch ON OFF WASH Switch is lo...

Page 12: ...ICE Series Electrical and Plumbing Requirements Page 8 Electrical and Plumbing Requirements ICE0250 ICE0305 ICE0400 5 6 ICE0500 and ICE0605 6...

Page 13: ...ICE Series Electrical and Plumbing Requirements Page 9 Electrical and Plumbing Requirements ICE0805 6 ICE855 6GA and ICE1005 6 7...

Page 14: ...ICE Series Electrical and Plumbing Requirements Page 10 Electrical and Plumbing Requirements ICE1405 6 7 ICE1806 7 and ICE2106 7...

Page 15: ...ICE Series Electrical and Plumbing Requirements Page 11 Electrical and Plumbing Requirements ICE0320 5 and ICE0520 5...

Page 16: ...ICE Series Electrical and Plumbing Requirements Page 12 Electrical and Plumbing Requirements ICE1506R5 Remote...

Page 17: ...d Plumbing Requirements Page 13 Electrical and Plumbing Requirements ICE1506HT Air Cooled Top Air Discharge Clearance Requirements for the ICE1506HT to insure proper air circulation Top 8 inches Back...

Page 18: ...ICE Series Electrical and Plumbing Requirements Page 14 Electrical and Plumbing Requirements ICE0726 and ICE0926 Remote...

Page 19: ...oving impurities and sediment This allows the machine to produce clear ice cubes and keep mineral build up at a minimum The hot gas solenoid opens allowing hot gas to go directly to the evaporator hea...

Page 20: ...nd Timer Adjustment Once the unit has gone through 1 or 2 harvest cycles verify that the ice production is per the chart below Batch Weights Models Half Cube Full Cube ICEU150 ICEU220 ICEU225 ICEU226...

Page 21: ...or The switch should close when the bottom edge of the curtain is even with the outer edge of the water trough Adjust the switch by loosening the nuts that hold the switch in place Move the switch to...

Page 22: ...er thickness and adjustment procedure 3 Check water level in trough See page 16 for proper water level and adjustment 4 Clean the condenser air cooled machines to insure unobstructed air flow 5 Check...

Page 23: ...n Required for cleaning and or sanitizing Cleaning Instructions Ice Machine 1 Initiate the wash cycle at the ICE OFF WASH switch by placing the switch in the WASH position Depress the Purge Switch to...

Page 24: ...ing or de liming an ice machine refers to the process of removing mineral buildup and scale from the evaporator and other components Ice O Matic recommends cleaning the ice machine at least every 6 mo...

Page 25: ...abrasive sponge pads wire brushes or scrapers to clean the metal 3 Don t use cleaners that use chlorine or chlorides Do not use chlorine bleach products to clean the metal surfaces Chlorides break dow...

Page 26: ...If ice is being made initiate harvest or wait for cycle completion 3 Place the ICE OFF WASH switch to the OFF position The switch is located in the control box 4 Disconnect the tubing between the wat...

Page 27: ..._____________________________________________________________________________ __________________________________________________________________________________________ _______________________________...

Reviews: