Connect the power
This is a cord-connected unit, and must be connected
to its own dedicated power supply. Check the
dataplate on the back of the machine for the voltage
and maximum fuse size and per the dataplate use
fuses or HACR circuit breakers.
Power Cords:
50 Hz models are equipped with a cord without plug.
When adding a plug, c
onnect the plug to the power
cord in compliance with the local electrical codes.
Select an appropriately certified plug based on the
country of use, current rating of the appliance and
suitability for use with 1.5 mm 2 x 3 conductor type
H05VV-F cord
Note: In case the power cord is damaged, it
must be replaced by a like cord. Replacement
cords are available from the manufacturer’s local
representative. Replacement should only be done
by a qualified technician to prevent possible risks.
The power cord plug will be the disconnect means for
the machine and must be accessible when the unit is
in its permanent location.
Follow All Local Codes - This Unit Must Be
Grounded. Do not use extension cords and do not
disable or by-pass ground prong on electrical plug.
Plug the power cord into the power supply.
Installation check list
•
Has the machine been installed indoors in an
environment suitable for it?
•
Have all of the shipping items and packaging been
removed?
•
Is the ice chute in the correct position?
•
Is the clear plastic curtain hanging down and free to
move?
•
Has the water supply been connected and
confirmed to not leak?
•
Has a properly sized and sloped drain tube been
attached?
•
Has the correct voltage power supply been
connected?
Front view of freezing compartment, right arrow points
to clear plastic curtain. It must hang freely. Left arrow
points to cube deflector, it must be positioned as
shown.
Front view of freezing compartment, shown without
Ice Chute. Left arrow points to Spray Platform, located
under cube deflector. Spray Platform inlet connects
to pump hose and is snapped into clip at back of
reservoir.
Spray
Platform
Drain Plug