-19-
080417_Service manual Base, Wok- and Install-Line E
8.2
Initialisation of the induction unit by PC/Laptop
The initialization of the CU sensors as well as the adjustments of pan detection and
performance can be done by means of the hyperterminal program. You will find exact
information for the handling of the hyperterminal program in chapter 9 „IR interface“.
IMPORTANT! Pay special attention whether you receive feedback signal from the PC/Laptop
after every changement. This will be the sign that the changement has been accepted.
12345
Entry to the mode of adjustment (password)
;
Initialize Cu sensor (temperature of the coil ca. 25°C) (excluding WOK)
N
Increase the mains current limit (+)
n
Decrease the mains current limit(-)
"
Save the limit of the mains current
T
Increment pan detection (+)
t
Decrement pan detection (-)
=
Save pan detection
-?
Leave the mode of adjustment
.
State software version
8.3
Change of the parameters
1.
Connect the RS232 connection cable to the PC/Laptop and straighten the IR-box to the left
lower corner of the ceran glass.
2.
Start HT2400 (see chapter 9) and turn unit on!
3.
By input of „12345“ the mode of adjustment is started. The following message appears on
the hyperterminal program:
IR= On
WELCOME REPAIRMEN
4.
Not valid for WOK. The parameters on the CPU can now be changed! The unit temperature
and the surrounding temperature have to be 25°C (+/-4°C). Press the key
„;“
. On the
console appears the message „please confirm“. Press the key
„;“
again. The CU sensor will
now be initialized to 25°C. The following message appears on the hyperterminal program:
save CU sensor : 25ºC