-13-
080417_Service manual Base, Wok- and Install-Line E
Number of
flashing signals
Error code
Signification
Measure to take
5
-.....-.....-.....-
Error on power switch
3)
a.
Check connection
b.
Check power switch
6
-......-......-......-
Temperature inside the unit
too high
3)
c.
Check whether the unit is next to a
source of heat as e. g. friteuse
d.
Check whether hot air is taken in –
generator has no air exhaust system
7
-.......-.......-.......-
Empty cooking sensor
1)
a.
Check cooking material in the pan
8
-........-........-........-
Sensor error
3)
a.
Check Cu sensor
b.
Check heat sink sensor
c.
Check RTCS-sensor
d.
Check board sensor
12
Power reduction, heat sink
temperature
2)
a.
Turn the power down
b.
Check fan
13
Power reduction,
temperature of cooking
surface 2)
CU sensor 1
Warning temperature
a.
Take pan off until cooking area has
cooled down
b.
Wait until it has cooled down
c.
Check coil
17
CU sensor 1
overtemperature
3)
a.
Temperature of the cooking field too
high
b.
Check CU sensor 1, index value 5Ohm
at 25ºC
18
CU sensor 2
overtemperature
3)
a.
Temperature of the cooking field too
high
b.
Check CU sensor 2, index value 5Ohm
at 25ºC.
19
CU sensor 2
warntemperature
a.
Temperature of the cooking field too
high
b.
Turn the power down
20
Power reduction generator
inside temperature
2)
a.
Check for heat sources around the
generator and remove them
b.
Check air circulation
21
Heat sink sensor error
3)
a.
Contact Inducs AG
24
Board temperatur sensor
error
3)
a.
Exchange power unit
25
CU sensor 1 error
3)
a.
Check CU sensor 1 for short circuit or
discontinuation, index value 5Ohm at
25ºC.
26
CU Sensor 2 error
3)
a.
Check CU sensor 2 for short circuit or
discontinuation, index value 5Ohm at
25ºC.
27
Empty cooking detector CU
sensor 1
1)
a.
Check cooking material in the pan
28
Empty cooking detector CU
sensor 2
1)
a.
Check cooking material in the pan