operating & maintenance manual

 – 

console water source heat pump (wshp)

6

operation

Normal Mode

1.  Press [ON/OFF] to turn on thermostat.

2.  Press [Mode] to change the system mode.

3.  There are three operation modes (Cool Mode,  

 

 

Heat Mode, Auto Mode). 

Cool Mode

• 

To activate cooling mode, press the mode  

 

 

 

button until COOL displays.

• 

Press up/down arrow keys to your desired  

 

temperature.

• 

Compressor will cycle when temperature  

 

reaches the set-point. After compressor  

 

 

 

stops, allow at least 3 minutes before  

 

restarting (this applies only if you have  

 

manually turned the unit off or reset the  

 

 

 

thermostat – during normal running  

 

conditions, the unit will automatically  

 

allow for the required restart delay). 

 

The temperature reading that is on constant  

display is the ambient room temperature. 

 

Heat Mode

• 

To activate heating mode, press the  

 

Mode button until HEAT displays.

• 

Press up/down arrow keys to your  

 

desired temperature.

• 

The unit will cycle until the set  

 

temperature is achieved and then will  

 

continuously cycle to maintain the set  

 

temperature. 

 

The temperature reading that is on constant display  

is the ambient room temperature. 

eVent tIme

heat

cool

mon-

FrI

waKe
leaVe
return
sleep

6:00 am
8:00 am 
6:00 pm 
10:00 pm

70º F (21º c) 
62º F (17º c) 
70º F (21º c) 
62º F (17º c)

78º F (26º c)
85º F (29.5º c) 
78º F (26º c) 
82º F (28º c)  

sat-

sun

waKe
leaVe
return
sleep

6:00 am
10:00 am 
6:00 pm 
11:00 pm

70º F (21º c) 
62º F (17º c) 
70º F (21º c) 
62º F (17º c)

78º F (28º c)
85º F (29.5º c) 
78º F (26º c) 
82º F (28º c)  

6:08

am

mON

WaKE

Auto Mode

• 

To activate auto mode, press the mode  

 

button until AUTO displays. 

• 

Press up/down arrow keys to set  

 

desired heat temperature.

• 

Wait 5 seconds for cool to appear.

• 

Press up/down arrow keys to set  

 

desired cool temperature.

• 

The unit will automatically cycle between  

 

heat and cool modes if unit exceeds desired  

 

set points. The temperature reading that is  

 

on constant display is the ambient room  

 

temperature. 

internal Setting

Enter internal setting mode by pressing and holding 

[Mode] key for 5 seconds

Summary of Contents for Console Water Source Heat Pump

Page 1: ...Console Water Source Heat Pump WSHP OPERATING MAINTENANCE MANUAL World class comfort ...

Page 2: ... 14 1 4 SECTION G G SCALE 1 10 HOLE FOR DRAIN HOSE JUNCTION BOX FRONT VIEW NOTES DIMENSIONS ARE SHOWN IN INCHES 1 OPTIONAL MOTORIZED WATER VALVE IS SHOWN 2 ALL DIMENSIONS ARE 1 4 3 LEFT HAND CONFIGURATION IS SHOWN 4 UNIT IS SHIPPED WITH UNIVERSAL LEFT HAND OR RIGHT HAND 5 PIPING CAPABILITY 6 OPTIONAL OUTSIDE AIR DOOR SHOWN 7 SUPPLY AND RETURN PIPES HAVE 1 2 THREADED FEMALE ADAPTER A B C D E 5HPW09...

Page 3: ...ed in a separate instruction sheet specific to that option On behalf of ICE AIR and our network of distributors and dealers we are happy to welcome you to our base of satisfied customers CONSUMER SAFETY AND OPERATING NOTES FOR SAFE AND OPTIMAL ENJOYMENT OF YOUR ICE AIR WSHP UNIT PLEASE READ THE FOLLOWING CONSUMER SAFETY AND OPERATING NOTES CAREFULLY BEFORE OPERATING YOUR EQUIPMENT This unit MUST b...

Page 4: ...circuit breaker for branch circuit overcurrent protection Consult the unit serial plate for current ratings All 208 230V units are wired for 208V operation unless otherwise specified The following physical conditions must be maintained for proper unit operation Unobstructed air flow into and out of the unit room enclosure cabinet Therefore Do not place furniture rugs or objects directly in front o...

Page 5: ...Power Control Board PCB The large LCD display panel includes clearly marked control buttons The Control pad is a programmable user friendly device that enables the user to program desired temperature settings and operational modes LCD Programmable Thermostat Feature list Operates on 2 stage Heat and 2 stage Cool 7 programs Mo Tu We Th Fr Sa Su or 5 2 programs Mo Fr Sa Su 4 Separate Time and Temper...

Page 6: ...perature The unit will cycle until the set temperature is achieved and then will continuously cycle to maintain the set temperature The temperature reading that is on constant display is the ambient room temperature EVENT TIME HEAT COOL MON FRI WAKE leave return SLEEP 6 00 AM 8 00 AM 6 00 PM 10 00 PM 70º F 21º C 62º F 17º C 70º F 21º C 62º F 17º C 78º F 26º C 85º F 29 5º C 78º F 26º C 82º F 28º C ...

Page 7: ...an when complete The cool limit setting should be at least 4 F higher than the heat limit setting The cool limit setting is 55 F to 95 F The heat limit setting is 51 F to 91 F Exit Internal Setting and Return to Normal Mode 1 Press Fan to confirm and return to normal mode 2 If no key is pressed for 15 seconds it will return to normal mode automatically Temporary Program Override 1 When thermostat ...

Page 8: ...anual assumes that your WSHP unit has been installed by a qualified installation professional and is operating properly prior to maintenance service Have your unit periodically inspected by a properly trained service professional or building maintenance staff person The unit should be checked for the safe and proper functioning of all of its systems at least once a year The following recommended m...

Page 9: ...n a facility properly equipped to handle this type of work in a safe and professional manner Drain Pan Drain Hose Cleaning The condensate pan is located directly under the evaporator coil Check the visible section of the interior of the drain pan for any buildup of dirt or condensate water Wash annually to remove all dirt build up Check condensate drain pan for algae growth every 2 to 3 months If ...

Page 10: ...east once a month Pay special attention to hose assemblies and connections Repair any leaks and replace deteriorated hose immediately to avoid potential costly damage to your property due to component failure TROUBLESHOOTING 1 If unit is not operating conduct the following checks If a flashing A appears on the display contact a trained technician Check the electrical connections Check the voltage ...

Page 11: ...ed Normal Off On Off High Pressure Off Off Flash Low Pressure Flash Off Off Evaporator too cold Flash Off Flash Coaxial winter protection Flash on off Temperature probe failure Off flash Off High low voltage Off Off On Condensate over flow on Off Off Coaxial water too cold on Off flash troubleshooting error code menu ...

Page 12: ...RES MUST BE SERVICED BY QUALIFIED TRAINED PERSONNEL ELECTRIC SHOCK HAZARD DISCONNECT FROM LIVE ELECTRIC CIRCUIT BEFORE SERVICING MOVING PARTS HAZARD DISCONNECT FROM LIVE ELECTRIC CIRCUIT BEFORE SERVICING UNIT MUST BE OPERATED WITH ALL CHASSIS SHEET METAL PARTS PROPERLY IN PLACE UNIT MUST BE OPERATED WITH ALL ENCLOSURE CABINET PARTS IN PLACE READ THIS ENTIRE OPERATIONS MANUAL BEFORE OPERATING THE U...

Reviews: