ICB TH-QR-24 Operation Manual Download Page 7

GAS APPLIANCE CODE COMPLIANCE 

 

The installation of gas piping from the outlet side of the gas meter or 

service regulator to the charbroiler must be performed by a technician  

qualified and certified or licensed to install gas-fired equipment. 

 

A licensed and qualified technician must perform the initial startup and 

adjustment of this appliance.

 

 

The installation of this gas-fired appliance must conform to local codes, 

or in the absence of such codes, with the current edition of 

National Fuel Gas Code ANSI Z223.1. 

 

The installation of this gas-fired appliance must comply with 

applicable portions of NFPA 96 for ventilation.  The current edition of 

NFPA 96 (

Standard for the Installation of Equipment for the Removal   

of Smoke and Grease Laden Vapors from Commercial Cooking     
Equipment

) specifies ventilation requirements to ensure the removal    

of exhaust gasses and products of combustion. 

 

IT IS THE RESPONSIBILITY OF THE INSTALLER TO ENSURE   

THAT THIS GAS GRIDDLE INSTALLATION CONFORMS TO ALL   

APPLICABLE CODES AND ORDINANCES. 

 

The venting of this appliance must not be obstructed, nor may such 

venting interfere with the flow of combustion air required for proper     

operation of the gas burners. 

 

Additionally: 

 

1.  The gas supply  line used to connect the appliance to the gas 

 

supply system must be black iron pipe, or other material as  

 

approved by local ordinance for gas piping. 

 

2.  Gas supply piping must be 3/4” inside diameter or greater. 

 

3.  Use pipe sealant made specifically for gas piping on all pipe  joints.  

 

Apply sealant sparingly to the male threads only. 

 

Sealant must be resistant to the action of LP gas.  

 

4.  Verify that all supply piping is clean and free of obstructions, dirt, 

 

chips and pipe sealant compound prior to installation. 

 

5.  All pipe joints must be checked for leaks before lighting.  Leak 

 

checks should be performed with a soap and water solution.  

 

NEVER CHECK FOR LEAKS WITH AN OPEN FLAME. 

 

 

INSTALLATION (continued) 

DANGER: 

FIRE AND 

EXPLOSION 

HAZARD 

NEVER use an open flame to 

check for gas leaks.  Fire and 

explosion may result. 

 

 

WARNING: 

RISK OF  INJURY 

 

Installation procedures must 

be performed by a qualified 

technician with full knowledge 

of all applicable gas-fired    

appliance codes.  Failure can 

result in personal injury and 

property damage. 

 

IMPORTANT: 

All pipe joints must be 

checked for leaks before 

lighting.  Leak checks should 

be performed with a soap and 

water solution. 

 

IMPORTANT: 

Information on the 

construction and installation 

of ventilating hoods may be 

obtained from the current 

edition of NFPA 96 

Standard for the Installation 
of Equipment for the Removal 
of Smoke and Grease Laden 
Vapors from Commercial 
Cooking Equipment

.  

Copies of this standard are 

available from the 

Nation Fire Protection Assn.: 

 

NFPA 

1 Batterymarch Park 

P.O. Box 9101 

Quincy, MA 02269-9101 

Summary of Contents for TH-QR-24

Page 1: ...o be part of the appliance and is to be given to the OWNER or MANAGER of the restaurant or to the person responsible for TRAINING OPERATORS of this appliance Additional manuals are available from your...

Page 2: ...h the equipment are not covered by this warranty 4 Replacement of items subject to normalwear to include such items as knobs light bulbs and normal maintenance functions including adjustments of therm...

Page 3: ...nt maintenance of this appliance will ensure that it gives you the very best performance and a long economical service life This manual contains the information needed to properly install this applian...

Page 4: ...UARD GRATE RAISED POSITION GRATE NORMAL POSITION GREASE DISCHARGE CHUTE GREASE TROUGH DRIP PAN ADJUSTABLE LEG CONTROL KNOB OFF POSITION CONTROL KNOB ON POSITION GAS PRESSURE REGULATOR GAS MANIFOLD RAD...

Page 5: ...be performed by a technician trained and certified in the maintenance of gas appliances Improper servicing of gas equipment can result in fire and explosion CAUTION HOT SURFACE Exposed surfaces can b...

Page 6: ...uction Sheet packed with the appliance before starting any installation Read and understand all labels and diagrams attached to the appliance Carefully account for all components and accessories befor...

Page 7: ...be black iron pipe or other material as approved by local ordinance for gas piping 2 Gas supply piping must be 3 4 inside diameter or greater 3 Use pipe sealant made specifically for gas piping on al...

Page 8: ...the gas supply piping and the gas pressure regulator It is the responsibility of the gas piping installer to identify the code requirement for a shut off valve Shut off valves moisture trap and all as...

Page 9: ...ADJUST BURNER FLAME Remove all burner control knobs then remove the front panel Remove grates and radiants Turn an individual burner on Loosen the locking screw on the shutter Turn the shutter to adm...

Page 10: ...will not turn by hand DO NOT attempt to force or repair it Contact your Authorized ICB Service Agency for repairs Forced or improperly repaired valves pose the risk of fire and or explosion Make sure...

Page 11: ...ergy by turning the temperature control knob OFF any time the griddle is not in use Gas burners provide full heat instantly making it unnecessary to leave the unit on during intermittent use To decrea...

Page 12: ...cles from the cabinet b Clean the cabinet with a soft damp cloth or sponge and mild detergent Rinse by wiping with a soft cloth moistened with clean water Dry with a soft cloth 5 Reassemble broiler a...

Page 13: ...d and mild detergent Dry thoroughly before reinstalling on burners Rinse by wiping with a soft cloth dampened with clean water Wipe exterior surfaces dry with a soft clean cloth Allow burners to air d...

Page 14: ...c Pilot burner not lit Turn off gas allow unit to vent for 5 minutes Turn gas back on and light pilot One burner assembly won t light Control not on Turn control knob to ON Set to desired setting when...