TROUBLESHOOTING
NOTE:
There
are
no
user
serviceable
components
in
the
burner
assemblies
or
in
the
control
valves.
In
all
cases
of
damage
or
malfunction,
contact
your
Authorized
ICB
Service
Agency
for
repairs.
SYMPTOM
POSSIBLE
CAUSE
SUGGESTED
REMEDY
Pilot
will
not
light
Gas
supply
off
Check
main
/
unit
gas
valves
Air
in
lines
Turn
pilot
valve
on.
Attempt
to
light
pilot
every
15
sec.
Pilot
valve
not
on
Turn
pilot
valve
on
/
adjust
Burners
won’t
light
Gas
supply
off
Check
main
/
unit
gas
valves
Air
in
lines
Turn
gas
valve
on.
Attempt
to
light
pilot
every
15
sec.
Pilot
burner
not
lit
Turn
off
gas
-
allow
unit
to
vent
for
5
minutes.
Turn
gas
back
on
and
light
pilot
One
burner
assembly
won’t
light
Control
not
on
Turn
control
knob
to
ON
Set
to
desired
setting
when
lit
Water
in
burner
Remove
burner
and
dry
thoroughly
Damaged
gas
control
valve,
burner
or
other
internal
component
Contact
Authorized
ICB
Service
Agency
for
repairs
Portions
of
a
burner
won’t
light
or
have
erratic
flame
Burner
wet
or
flame
opening(s)
clogged
Clean
and
dry
burner
Burner
not
hot
enough
Temperature
control
not
set
Adjust
for
desired
temperature
Shutter
or
nozzle
out
of
adjustment
Contact
qualified
technician
for
adjustment
Damaged
gas
control
valve,
burner
or
other
internal
component
Contact
Authorized
ICB
Service
Agency
for
repairs