iCanView230/230W User’s Guide
y
DC7-23V, 8W:
Power input of iCanView230/230W.
Do not apply power through this power input when power is applied through LAN cable using
proprietary PoE.
y
RS-485 and ALARM IN/OUT : Used for connecting P/T device, sensor, and alarm devices to
iCanView230/230W. Note that the bottom most pin is numbered as 1. Pin assignments are as
follows
Pin
Description
Misc.
1
RS-485 Negative (-)
2 RS-485
Plus
(+)
3
Alarm In (-)
NC/NO selectable in admin mode.
4
Alarm In (+)
NC/NO selectable in admin mode.
5 Alarm
Out
6 Alarm
Out
Relay output : closed circuit in alarm
to indicate alarm status.
RS-485 :
Used for connecting Pan/Tilt and Zoom devices having RS-485 interface
standard.
Alarm In :
Connect external alarm sensors such as the
infrared sensors, heat
sensor, magnetic sensors, etc. NC/NO selectable in the admin page.
Alarm Out :
It is used for connecting external alarm generators such as sirens,
flashing light, etc. When activated, relay output configures a closed circuit.
Please refer to Section 6.1 for more detailed description on the Alarm In/Out
connections.
y
Reset :
Factory Default Switch
There is a switch provided for returning the network camera to factory default state. Press the
switch about 3 seconds through a tiny hole at the left of the 100BaseT connector using tools
with sharp tip for a few seconds while power is applied.
y
Antenna Connector :
Connector for connecting 3dBi antenna supplied with
iCanView230W
Rev.1.0 (Aug. 2006)
10 of 54