ICA SE1000 Operating Manual Download Page 6

3.

 

INSTALLATION 

 

3.1.

 

Receipt Of The UPS 

o

 

When unpacking the UPS, please pay attention to the packing mode and the 
annex in which includes user-manual, warranty card, input power cable, 
output wiring socket. 

o

 

Inspect your machine to see whether it’s damaged in the transportation. If 
damaged or some parts missing, please inform the transformer or the 
franchiser, don’t start up your UPS. 

o

 

Check if the equipment is just what you wanted to purchase. You can affirm 
through inspecting the model number on back panel of the equipment. 

 

3.2.

 

Safety Notes

 

o

 

Keep good circulation around UPS and far away from water, flammable gas 
and corrosive. 

o

 

Don’t place UPS on the slope and there should keep good air circulation 
between in-vent on front panel bottom and fan out-vent on back panel. 

o

 

The environment temperature around UPS should keep in a range of 0 

0

C ~ 

40 

0

C. 

o

 

There will be phenomena of condensing if the equipment is dismantled or 
installed under low temperature. The equipment can’t be installed unless it 
is full dry at internal and external of the equipment, otherwise, there will be 
danger of electric shock. 

 

Note : 

o

 

W en connecting load to UPS, first turn off load and the connect the 

h

power cable and finally turn on load one-by-one. 

o

 

Plug UPS on the special power receptacle with over-current 
pr ection, the power receptacle should be connected with ground 

ot

wire. 

o

 

It is recommended the batteries are charged for eight hours prior to 
use. UPS can automatically charge batteries as long as UPS put 
through power. UPS can also be used at once if battery hasn’t been 
charged, but the back-up time will be less than the standard value. 

o

 

When connect inductance load such as laser printer to UPS, the 
capacity of UPS is reckoned according to the loads startups power 
because the startup power is higher. 

 
 
 
 

 

5. PERAWATAN

 

 

UPS seri frekuensi tinggi membutuhkan sedikit perawatan. Batterai standar 
yang digunakan adalah yang terregulasi, bebas perawatan. Dapat digunakan 
untuk waktu yang lama hanya dengan menjaga keteraturan pengisiannya. 
Tanpa diperhatikan apakah UPS START ataupun STOP asalkan UPS 
terhubung dengan jala-jala, batterai akan diisi sepanjang waktu dan UPS 
memberikan perlindungan jika terjadi pengisian dan pembuangan muatan yang 
berlebih. 

 

Dianjurkan untuk mengisi batterai setiap empat sampai enam bulan sekali jika 
UPS tidak digunakan dalam waktu yang lama. 

 

Normalnya daur batterai adalah tiga sampai lima tahun dan batterai harus 
diganti lebih awal jika terjadi kondisinya tidak normal. Untuk menggantikan 
batterai harus oleh seorang yang memiliki kualifikasi. 

 

Tidak bijaksana jika mengganti hanya salah satu batterai. Pengguna sebaiknya 
mengikuti petunjuk distributor battery ketika mengganti seluruh batterai. 

 

Batterai sebaiknya di isi dan buang muatan sekali dalam enam bulan. Setelah 
UPS buang muatan sampai mati, batterai sebaiknya di isi ulang. Waktu untuk 
mengisi batterai harus lebih dari duabelas jam. 

 

Batterai harus di isi dan buang muatan sekali dalam dua bulan pada area 
bersuhu tinggi. Waktu untuk mengisi batterai harus lebih dari duabelas jam. 

 
 

Perhatian : 

o

 

Se elum mengganti batterai, pertama-tama putus hubungan dengan 

b

jala-jala dan lepaskan semua aksesoris logam seperti cincin, jam 
tangan dan sejenisnya. 

o

 

Gunakan obeng dengan gagang terisolasi. Jangan menempatkan 
peralatan atau ogam diatas batterai. 

o

 

Wajar terjadi percikan ketika memasang kabel ke batterai, tidak 
akan membahayakan. 

o

 

Hindari hubung singkat antara kutub positif dan kutub negatif 
bat erai. 

t

 

 
 
 
 
 

 

Page 3

 

Hal 12

Summary of Contents for SE1000

Page 1: ...UPS OPERATING MANUAL Uninterruptible Power System SE1000 SE2000 SE3000 481 11H0010 110...

Page 2: ...SERVICE CENTRE Jln Pinangsia I No 22BB Jakarta Barat Phone 62 21 6906020 Hunting Contact Support on www icaups co id...

Page 3: ...ON 3 3 1 Receipt Of The UPS 3 3 2 Safety Notes 3 3 3 UPS Rear Panel 4 3 4 The Description Of Front Panel And Display Lamp 6 3 4 1 LCD panel section 6 3 4 2 LED indicators function 6 3 4 3 Button part...

Page 4: ...ower blackout UPS would transfer to battery mode to supply power to loads when battery voltage is low UPS would protect itself and shuts down automatically When main power restores UPS would be turned...

Page 5: ...igital fault codes and the fault information codes checking table 2 SAFETY Even if not connected to main power high voltage may still presents at UPS outlets If external battery cord or power cord nee...

Page 6: ...ect inductance load such as laser printer to UPS the capacity of UPS is reckoned according to the loads startups power because the startup power is higher 5 PERAWATAN UPS seri frekuensi tinggi membutu...

Page 7: ...l informasi Perhatian o Pro edur dibawah ini harus dilakukan jika UPS dihubungkan s dengan generator Pertama hidupkan generator setelah berfungsi stabil yakinkan tidak ada beban yang terhubung ke UPS...

Page 8: ...nyi tekan dan tahan tombol function selama 1 detik atau lebih maka buzzer akan berbunyi kembali o Jika penunjuk grafis kapasitas batterai pada display baris ketiga pada display LCD berkedip LED kuning...

Page 9: ...TERY OUTPUT LOAD TEMP 8 8 8 8 8 LED Red light LED Yellow light LED Green light Fig 3 Description of the front panel 3 4 1 LCD panel section o The first line is the numeric section and is consisted of...

Page 10: ...en UPS is started with the utility in and LCD displays on batt which means UPS is working in battery mode 4 1 3 Mematikan UPS pada mode utility o Tekan dan tahan tombol START OFF lebih dari 2 detik un...

Page 11: ...ah sama dengan menghidupkan UPS menggunakan jala jala dan display LCD menampilkan on batt yang berarti UPS bekerja dalam mode batterai 4 1 3 Turn off UPS in utility mode o Press and hold the START OFF...

Page 12: ...Z INPUT RST BATTERY OUTPUT LOAD TEMP 8 8 8 8 8 LED Merah LED Kuning LED Hijau Gbr 3 Penjelasan panel depan 3 4 1 Bagian panel LCD o Baris pertama adalah bagian angka terdiri dari dua bagian angka dan...

Page 13: ...cond the buzzer will stop beeping press and hold the FUNCTION button for one more second the buzzer will beep again o If battery capacity graph in the graphic section the third row on LCD display flas...

Page 14: ...e o The following process must be performed if the UPS is connected with generator First turn on generator after it runs stably at this time ensure UPS is no load connected connect output power of gen...

Page 15: ...jala jala o t Ke ika menghubungkan beban induktif seperti pencetak laser ke UPS kapasitas UPS disesuaikan dengan daya pada beban karena dayanya lebih tinggi 5 MAINTENANCE High frequency series UPS ne...

Page 16: ...kode kesalahan pada LCD dan memeriksa table informasi kesalahan 2 KESELAMATAN Meskipun tidak terhubung dengan sumber tegangan tegangan tinggi masih mungkin terdapat di keluaran UPS Jika kabel externa...

Page 17: ...r benar proteksi sumber daya yang ramah lingkungan Fungsi Smart Management Saat tegangan jala jala terputus UPS akan berpindah ke mode batterai untuk mensupplai daya ke beban ketika tegangan batterai...

Page 18: ...3 PEMASANGAN 3 3 1 Penerimaan UPS 3 3 2 Catatan Keselamatan 3 3 3 Panel Belakang UPS 4 3 4 Penjelasan Panel Depan Dan Lampu Display 6 3 4 1 Bagian panel LCD 6 3 4 2 Fungsi petunjuk LED 6 3 4 3 Fungsi...

Page 19: ...SERVICE CENTRE Jln Pinangsia I No 22BB Jakarta Barat Phone 62 21 6906020 Hunting Contact Support on www icaups co id...

Page 20: ...BUKU PETUNJUK PEMAKAIAN Uninterruptible Power System SE1000 SE2000 SE3000...

Page 21: ......

Reviews: