background image

1.

 

INTRODUCTION 

 

 

This UPS is sophisticated piece of equipment with 16 bit microprocessor and 
advanced software programming technology, high frequency SPWM is created 
to control the inverter of UPS. This simplifies the control circuit, enhances the 
stability of UPS, also enables the UPS to have enhanced real-time performance 
that makes UPS respond the variety of external environment rapidly and insure 
that the control circuit is compact and reliable. 

 

Digital control technology to avoid the temperature excursion of hardware 
specification. 

 

Self-diagnoses before startup help UPS to find potential failure to avoid any 
losses. 

 

Double conversion on-line topology, which makes the UPS a pure sine wave 
machine with constant frequency, constant voltage, low noise and no 
interruption with mains power fluctuation. It protect the user’s equipment 
ideally all the time. 

 

No transfer time when main power fail or main power restore, meets the 
requirements of precision instruments. 

 

Standard bypass function, when UPS meets a faults, it can transfer to bypass 
seamlessly and provide alarm. 

 

Advanced voltage compensation technology, makes the wide input voltage 
range, reducing the battery usage, enhancing the adaptive ability against the bad 
mains power variation. 

 

Advanced wide frequency input technology, wide input frequency range of 
UPS gives UPS a good compatibility with generator under field circumstances. 

 

The advanced PFC technology on the input of UPS, improves the input power 
factor close to unity, raises the power efficiency, removes the harmonic noise 
from UPS to utility, lowers UPS operational costs, it’s really a environmental 
friendly protection power supply. 

 

Smart Management Function. Under mains power blackout, UPS would 
transfer to battery mode to supply power to loads, when battery voltage is low, 
UPS would protect itself and shuts down automatically. When main power 
restores, UPS would be turned on automatically to supply power to loads. 

 

Cold start function, when there is no input, UPS can be turned on with battery 
pack, to meet the user’s emergency needs. The cold start function is quite 
strong. UPS can be cold started on full load situation. 

 
 
 
 

 

6.2. Tabel Ketidak Normalan

 

 

Masalah

Penyebab 

 

Solusi

Tegangan atau 
frekuensi jala-jala 
mendekati batas 
input UPS (bunyi 
2 kali tiap 1 detik 
ketika startup, 
bunyi sebanyak 8 
kali) 

UPS bekerja dalam mode batterai, 
simpan data dan tutup programs, 
yakinkan tegangan dan frekuensi jala-
jala berada dalam batas normal. 

Muncul pesan 
“INPUT” pada 
display. 

Koneksi fase jala-
jala dan netral 
terbalik, UPS 
bunyi 2 menit 
sekali 

Pasang kembali, yakinkan koneksinya 
benar. 

Indikator 
batterai 
berkedip 

Tegangan batterai 
rendah atau 
batterai tidak 
terpasang 

Periksa batterai UPS, pasang kembali 
batterai dengan baik, jika batterai 
rusak, segera gantikan. 

Jala-jala 
normal, tapi 
tidak ada input 
UPS 

Breaker input 
UPS terbuka 

Kembalikan breaker ke posisi semula. 

Batterai tidak 
cukup terisi 

Tetap hubungkan UPS dengan jala-jala 
lebih dari 8 jam, mengisi batterai. 

Beban lebih pada 
UPS 

Periksa kapasitas beban, lepas beberapa 
beban. 

Back-up 
sebentar 

Batterai rusak 

Lepas batterai, hubungi agen kami 
untuk mendapatkan batterai dan suku 
cadang lainnya. 

Waktu penekanan 
tombol sebentar 

Tekan dan tahan tombol ON lebih dari 
1 detik untuk menghidupkan UPS. 

Tidak ada batterai 
terpasang atau 
tegangan batterai 
rendah dan terlalu 
banyak beban 
terpasang 

Pasang UPS dengan batterai, jika 
tegangan batterai rendah, matikan UPS 
dan lepaskan beberapa beban, lalu 
hidupkan kembali UPS. 

UPS tidak 
hidup setelah 
tombol ON 
ditekan 

Kerusakan terjadi 
dalam UPS 

Hubungi service centre kami. 

 

Page 1

 

Hal 14

Summary of Contents for SE1000

Page 1: ...UPS OPERATING MANUAL Uninterruptible Power System SE1000 SE2000 SE3000 481 11H0010 110...

Page 2: ...SERVICE CENTRE Jln Pinangsia I No 22BB Jakarta Barat Phone 62 21 6906020 Hunting Contact Support on www icaups co id...

Page 3: ...ON 3 3 1 Receipt Of The UPS 3 3 2 Safety Notes 3 3 3 UPS Rear Panel 4 3 4 The Description Of Front Panel And Display Lamp 6 3 4 1 LCD panel section 6 3 4 2 LED indicators function 6 3 4 3 Button part...

Page 4: ...ower blackout UPS would transfer to battery mode to supply power to loads when battery voltage is low UPS would protect itself and shuts down automatically When main power restores UPS would be turned...

Page 5: ...igital fault codes and the fault information codes checking table 2 SAFETY Even if not connected to main power high voltage may still presents at UPS outlets If external battery cord or power cord nee...

Page 6: ...ect inductance load such as laser printer to UPS the capacity of UPS is reckoned according to the loads startups power because the startup power is higher 5 PERAWATAN UPS seri frekuensi tinggi membutu...

Page 7: ...l informasi Perhatian o Pro edur dibawah ini harus dilakukan jika UPS dihubungkan s dengan generator Pertama hidupkan generator setelah berfungsi stabil yakinkan tidak ada beban yang terhubung ke UPS...

Page 8: ...nyi tekan dan tahan tombol function selama 1 detik atau lebih maka buzzer akan berbunyi kembali o Jika penunjuk grafis kapasitas batterai pada display baris ketiga pada display LCD berkedip LED kuning...

Page 9: ...TERY OUTPUT LOAD TEMP 8 8 8 8 8 LED Red light LED Yellow light LED Green light Fig 3 Description of the front panel 3 4 1 LCD panel section o The first line is the numeric section and is consisted of...

Page 10: ...en UPS is started with the utility in and LCD displays on batt which means UPS is working in battery mode 4 1 3 Mematikan UPS pada mode utility o Tekan dan tahan tombol START OFF lebih dari 2 detik un...

Page 11: ...ah sama dengan menghidupkan UPS menggunakan jala jala dan display LCD menampilkan on batt yang berarti UPS bekerja dalam mode batterai 4 1 3 Turn off UPS in utility mode o Press and hold the START OFF...

Page 12: ...Z INPUT RST BATTERY OUTPUT LOAD TEMP 8 8 8 8 8 LED Merah LED Kuning LED Hijau Gbr 3 Penjelasan panel depan 3 4 1 Bagian panel LCD o Baris pertama adalah bagian angka terdiri dari dua bagian angka dan...

Page 13: ...cond the buzzer will stop beeping press and hold the FUNCTION button for one more second the buzzer will beep again o If battery capacity graph in the graphic section the third row on LCD display flas...

Page 14: ...e o The following process must be performed if the UPS is connected with generator First turn on generator after it runs stably at this time ensure UPS is no load connected connect output power of gen...

Page 15: ...jala jala o t Ke ika menghubungkan beban induktif seperti pencetak laser ke UPS kapasitas UPS disesuaikan dengan daya pada beban karena dayanya lebih tinggi 5 MAINTENANCE High frequency series UPS ne...

Page 16: ...kode kesalahan pada LCD dan memeriksa table informasi kesalahan 2 KESELAMATAN Meskipun tidak terhubung dengan sumber tegangan tegangan tinggi masih mungkin terdapat di keluaran UPS Jika kabel externa...

Page 17: ...r benar proteksi sumber daya yang ramah lingkungan Fungsi Smart Management Saat tegangan jala jala terputus UPS akan berpindah ke mode batterai untuk mensupplai daya ke beban ketika tegangan batterai...

Page 18: ...3 PEMASANGAN 3 3 1 Penerimaan UPS 3 3 2 Catatan Keselamatan 3 3 3 Panel Belakang UPS 4 3 4 Penjelasan Panel Depan Dan Lampu Display 6 3 4 1 Bagian panel LCD 6 3 4 2 Fungsi petunjuk LED 6 3 4 3 Fungsi...

Page 19: ...SERVICE CENTRE Jln Pinangsia I No 22BB Jakarta Barat Phone 62 21 6906020 Hunting Contact Support on www icaups co id...

Page 20: ...BUKU PETUNJUK PEMAKAIAN Uninterruptible Power System SE1000 SE2000 SE3000...

Page 21: ......

Reviews: