– 8 –
Trouble Shooting
Won’t Start:
1. Is it plugged it correctly. Extension cords should
be 14 gauge, grounded.
2. Check wall outlet circuit breaker or fuse. Motor
draws 3 amps (Duster 600), 10 amps (Duster
2000). Most breakers are 15 amps.Usually
you cannot run other large machinery on the
same circuit.
Filter Cleaning Gauge Problems:
• Please call factory if your gauge stops working
for any reason.
Filter Problems:
• CAUTION: Paint overspray, oil and glue mists,
will destroy the HP-16 pleated filters.
Always keep the green pads in place
in front of them.
• To get the longest filter life out of carbon filters
keep them clean. Dust plugs the carbon pores.