Danger of injury by rotational parts of the machine! 
When  operating,  maintaining  or  otherwise  manipulating  the  camera 
carriage and the cable winder, keep  in mind that these devices include 
rotational  components  (cogwheels,  chains,  etc.),  which  can  cause 
serious damage to your limbs or parts of your clothes.   

 

Risk of eye damage! 
The  camera  head  is  equipped  with  laser  diodes,  which  represent  a 
hazard for the eyes. Never look into the laser sources, even if they are 
not  activated.The  camera  head  and  the  additional  lights  are  equipped 
with a very powerful light source, which can damage your eyes or eyes 
of  people  around  them.  Ensure  that  the  lights  are  always  switched  off 
when they are away from the piping to prevent injury. 
 
Danger of injury by non-rotational parts of the machine! 
When moving a reel or control unit, consider the weight of the device. 
The dropping or overturning of the device could cause a loss of stability, 
resulting in danger of injury. Do not tilt the device so that tipping. 

 

Danger caused by contamination of pure water!   
Never  use  the  inspection  system  alternatively  for  inspections  in  waste 
water  and  pure  water!  Even  thorough  cleaning  of  the  system  cannot 
guarantee adequate protection against contamination.   
Use, a special system for inspections in waste water and pure water.  
 
When  assembling  components  containing  thread,  use  the  grease  and 
the  corresponding  sealing  elements  for  maximum  tightness.  When 
tightening the threads do not use too much force to prevent tearing or 
damage to the components. 
 
The  camera  head  and  other  components  coming  into  contact  with 
liquids are protected  against ingress of moisture and water by internal 
pressurizing.  The  pressure  is  indicated on the  LCD  panel of the  control 
unit.  Before  starting  work,  you  must  ensure  the  pressure  status  of  the 
individual components. This should ideally be 0.45 Bar. When you drop 
below 0.2 bar pressure must be completed. At low pressure threatens to 
damage  due  to  moisture  from  entering  the  camera  body  or  its  parts. 
Ideally nitrogen pressure charge, respectively. dry air with the pressure 
reducing  valve.  Pressure  above  0.55  bar  effortlessly  seal  cameras  and 
increases  its  wear.  Pressure  over  1  bar  is  critical  and  can  damage  the 
equipment for leaks. 

 

 

Warning!   
Operator of the equipment is responsible for proper waste disposal!  

 

 

Summary of Contents for REVI250 USB

Page 1: ... User s manual v1 4 07 2017 Manual for safe operation of the monitoring system and its maintenance to ensure trouble free operation All registered marks and trademarks mentioned in the guide are owned by the corresponding owners ...

Page 2: ...nly if it is correctly maintained and operated Guide purpose This guide serves as a manual for commissioning using and maintaining the monitoring system produced by IBOS a s and includes also important safety instructions Read this guide before start working with this system Pay attention to articles on safety that protect your health and prevent hazards connected with operation of the whole syste...

Page 3: ...g Different usage or usage beyond this scope is not considered the corresponding application Never use this inspection system for different purposes The system must not be used in piping with media subject to explosion For this purpose special equipment marked is specially produced and approved Type labels You can find type labels with the corresponding serial number on the individual components Y...

Page 4: ...l sheets for maintenance and care regular checking of the personnel for conscious work as regards safety and hazards Personal safety The person responsible for operation maintenance and additional modifications of the equipment must be specialists or trained by a specialist The specialists must have adequate knowledge in inspection systems through special training and experience They are acquainte...

Page 5: ...ipment beyond operations described in this manual can only be performed by a specialized trained person Larger maintenance or repairs can only be performed by the IBOS a s customer service or persons authorized by the IBOS a s Company Before cleaning maintenance and repair unplug apparatus from wall socket or power supply and follow the User s manual Danger of serious injuries caused by a touch of...

Page 6: ... inspection system alternatively for inspections in waste water and pure water Even thorough cleaning of the system cannot guarantee adequate protection against contamination Use a special system for inspections in waste water and pure water When assembling components containing thread use the grease and the corresponding sealing elements for maximum tightness When tightening the threads do not us...

Page 7: ...d connectors Axial camera head Camera head is connected to reel by special connector and can be equiped with Front Skids Conpatability of Control units and camera heads REVI100 push camera The camera has an image stabilization circuit integrated LED light and operates in diameters from 40 to 100mm Cable length is usually from 10 to 20m The light is provided by 4 LEDs It is possible to center the c...

Page 8: ...page 7 Parts of the system Axial camera centering part assembly ...

Page 9: ...en LED POWER off the device is completely switched off on the green switch is turned on or the power cable is connected Yellow LED CHARGING off the power cable is not connected flashing battery is charged on the battery is fully charged and the power cable is still connected Red LED LOW BATTERY off from 100 to 20 of charge on less than 20 of charge flashing less than 10 of charge Do not expose the...

Page 10: ...s and REVI250 or REVI350 push rod reels Control panel REVI250 USB Monitoring The fibreglass cable pushes the camera head forward throught the pipes The exact lenght of the extended cable is shown on the monitor in meters During the monitoring of wider pipes and sewers use the front skids USB 2 0 Light control On Off power On Off Sonde or REVI100 On Off USB recorder The flashing of the LED indicate...

Page 11: ...case of the recording video from monitoring to USB SD it is needed to have the USB SD recorder turned on by Camera DVR button Modes USB recorder firmware v2 1 Live video Back press to switch between the USB disc and interna SD card only when the both are present Stop if we press and hold 2 seconds to enter setup Play Pause switch to thumbnail recorded videos Forward Snapshot snapshot live video Re...

Page 12: ... and the free space falls below 10 capacity of the media it will start to delete the oldest files Auto delete only deletes the files created by the recorder other files will remain intact Playback Back does nothing Stop stop stops recording and returns to display thumbnail images Play Pause pause Forward Snapshot saves a sreenshot Record pause in browsing viewing When playing the green LED lights ...

Page 13: ...rd does nothing Copying of all files from the internal memory to a flash disk If any file is selected highlighted by the red line press consecutively the keys Back and Forward After dialog appears press the Play key to start the copying of all files The SD card must have a write rate of min Flash disk must be formatted to FAT32 USB recorder supports Flash in size max 2TB FAT32 limit For recording ...

Page 14: ...page 13 USB recorder Menu structure ...

Page 15: ...Ctrl F3 Set DATE Ctrl F4 Set TIME Ctrl F6 Set title line text Ctrl F7 Store Save the entire editor area text to the memory Pages 1 10 Ctrl F8 Store Save the text from start of actual line to cursor position to the memory Lines 1 100 Ctrl F9 Recall Paste the entire page from memory Ctrl F10 Recall Paste text from saved lines 1 100 to cursor position Alt F1 DATE on off Alt F2 TIME on off Alt F3 DIST...

Page 16: ...ext two numbers 0 to 9 to complete the three digit number You do not need to hold the Alt key for the second and third digit number The fix text line will be loaded immediately whenever you entered a valid three digit number If you press a non digit key the process of recalling a fix text page is aborted Screen Configuration Screen configuration with title line at the top date time and distance at...

Page 17: ...aintenance common wear or inevitable accidents lightning fire frost are exempt from the guarantee The warranty does not cover quickly worn out components such as the front glass shaft sealing rings light bulbs cables etc or damages that have no negative effect on usability of the equipment If you wish to claim a warranty contact IBOS a s Company our business representatives or the nearest customer...

Page 18: ... control panel main switch junction boxes transformer DC source LCD display 4 The reel for the cable Disclaimer We declare that this product complies with the technical requirements that apply to it and the product follows the guidelines of the European Union and the Government of the Czech Republic List of technical regulations Czech Republic Goverment Regulation No 17 2003 Czech Republic Goverme...

Reviews: