Switch off the pump should be performed in this order: 

First 

the pump must be disconnected, and then the aggregate can be switched off. Switching 

off the aggregate with a connected pump can result in pump motor getting burnt. In such a 
case, only paid repair is available. 

STORAGE: 

The cleaned pump must be stored in a dry room. 
Attention must be paid so that the whole length of the pump is placed on an even surface. 
Supporting pump in one or more points can lead to pump deflection which can result in failure. 

DEVICE DISPOSAL: 

the  used  product  is  subject  to  disposal  as  wastes  only  in  selective  waste 
collection  systems  organised  by  the  Network  of  Communal  Electric  and 
Electronic Waste Collection Centres. the customer is entitled to return the used 
equipment to the network of the electric equipment distributor, at least for free 
and directly, if the returned device is of proper type and fulfils the same function 
as a newly purchased device. 

EC DECLARATION OF CONFORMITY (Module A): 

 

PHU DAMBAT address: Gawartowa Wola 38, 05-085 KAMPINOS 
Under the Act of 30 August 2002 on the conformity system (Journal of Laws of 2004, No. 204 item 2087) we 
declare with full responsibility that pumps included in the series 3SDm, 3SD, 3ti, 3t2i, 3SKm, 4SKm, 4SCR, 
4SD, 4SDm, 3,5”SCM, 3,5”SCR, 90MSC, 4SKt, 3SQIBO, DWP, STING, SPm, SP, 3”SCR, 4ISP,6ISP.4ISPM, 
FL, OLA, STm to which this declaration refers to are consistent with the following guidelines of the Council 
on legal regulations unification in member states of EC: 

1)   MD  2006/42/EC  (applied  standards  EN  292-1:1991,  EN  292-2-1991/A1:  1995,  PN- 

EN 809:1999/AC: 2004) 

2)  EMC 2004/108/EC (applied standards PN-EN 55014-1:2004, PN-EN 61000-3-2:2004) 
3)   LVD 2014/35/EU (applied standards, PN EN 60335-1:2012, PN EN 60335-2-41:2012) 

Adam Jastrzębski 

02.10.2017 

POSSIBLE OPERATION PROBLEMS AND TROUBLESHOOTING 

Sign:

 

Possible cause:

 

Problem solution:

 

The pump does not 
operate

 

Security  device  protecting 
against 

dry 

operation 

triggered

 

Wait until the water amount in the well is sufficient for 
automatic pump launch.

 

Overcurrent  security  device 
triggered

 

Check if there is an overload. Remove the cause. Wait until 
the motor cools down and switch on the pump by means of 
the switch built in the protecting cable box.

 

 

 

 

PUMP MATCHING WITH POWER GENERATOR: 

The  power  of  the  rated  current  of  the  power  generator,  due  to  its  high  starting 
current, should be 3 to 5 times higher than the rated current power of the supplied 
motor. 

On  pump  launch  the  following  rule  must  be  observed:  the  pump  can  only  be 
connected upon the power generator launch. If the aggregate is switched on with a 
connected pump, it can lead to burning of the pump motor. in such a case, only 
paid repair is available. 

Summary of Contents for 3SDm

Page 1: ...ended for use by persons including children with reduced motor sensory or mental capacities or persons without experience or not familiarised with the equipment unless it is performed under supervisio...

Page 2: ...in two elements One element is a hydraulic part of the pump the other is a motor Prior to connection of two elements the clamping screws must be unscrewed from the strip protecting the cable Next the...

Page 3: ...p is to operate has wider diameter than specified in the table the pump must be installed in a special jacket forcing the proper cooling In pic the idea of such a jacket is presented The pump must be...

Page 4: ...with rated making current In not exceeding 30 mA The manufacturer and guarantor are not liable for any damage to people or property resulting from supplying the pump with power without a proper switch...

Page 5: ...assign such installation to a well fitter or they can do it in the shop of the well purchase Unprofessional connection and insulation of the cables can lead to automatic trigger of the residual curren...

Page 6: ...R 4SD 4SDm 3 5 SCM 3 5 SCR 90MSC 4SKt 3SQIBO DWP STING SPm SP 3 SCR 4ISP 6ISP 4ISPM FL OLA STm to which this declaration refers to are consistent with the following guidelines of the Council on legal...

Page 7: ...d the level onto which the water is pumped the length of the pumping pipeline hose and its diameter are factors which influence the height of lifting that must be performed by the pump If the resistan...