Complete the following steps to install a power supply:
1. Review the information in “Safety” on page v and “Installation guidelines” on
page 5.
2. (Some models) Remove the power-supply blank from the empty power-supply
bay by pinching the side clip and pulling the power-supply blank from the bay.
Save the power-supply blank in case you remove the power supply at a later
time.
Attention:
During normal operation, each power-supply bay must have either
a power supply or power-supply blank installed for proper cooling.
3. Move the handle on the power supply into the open position and slide the power
supply into the chassis.
4. Gently close the handle to seat the power supply into the bay.
5. Plug the power cord for the new power supply in the power-cord connector on
the back of the server.
6. If you have other options to install or remove, do so now; otherwise, go to
“Completing the installation”.
Note: When you turn on the server, verify that the dc power LED and ac power
LED on the power supply are lit, indicating that the power supply is operating
correctly.
Completing the installation
Complete the following steps to complete the installation:
1. Install the top cover.
2. Install the server in a rack. See the Rack Installation Instructions that come with
your server for complete rack installation and removal instructions.
Attention:
v
Install your server only in a rack cabinet with perforated doors.
v
Do not leave open spaces above or below an installed server in your rack
cabinet. To help prevent damage to server components, always install a blank
filler panel to cover the open space and to help ensure proper air circulation.
See the documentation that comes with your rack cabinet for more
information.
v
Install your server in a rack that meets the following requirements:
– Minimum depth of 70 mm (2.76 in.) between the front mounting flange and
the inside of the front door.
– Minimum depth of 157 mm (6.18 in.) between the rear mounting flange
and the inside of the rear door.
– Minimum depth of 718 mm (28.27 in.) and maximum depth of 762 mm
(30.00 in.) between the front and rear mounting flanges.
3. Plug in all cables and power cords.
The following illustrations show the locations of the input and output connectors on
your server. Detailed cabling instructions are in the Rack Installation Instructions
that come with your server.
Notes:
1. You must turn off the server before connecting cables to or disconnecting any
cables from the server (see “Turning off the server” on page 22).
Chapter 2. Installing options
17
Summary of Contents for xSeries 345
Page 3: ...IBM xSeries 345 Type 8670 Installation Guide SC48 P971 40 ...
Page 38: ...26 IBM xSeries 345 Type 8670 Installation Guide ...
Page 46: ...34 IBM xSeries 345 Type 8670 Installation Guide ...
Page 60: ...48 IBM xSeries 345 Type 8670 Installation Guide ...
Page 70: ......
Page 71: ...IBM Part Number 48P9726 Printed in the United States of America 48P9714 ...