IBM WDA L160 Manual Download Page 5

05        HD06         I/O                   06         HD09         I/O 
07        HD05         I/O                   08         HD10         I/O 
09        HD04         I/O                   10         HD11         I/O 
11        HD03         I/O                   12         HD12         I/O 
13        HD02         I/O                   14         HD13         I/O 
15        HD01         I/O                   16         HD14         I/O 
17        HD00         I/O                   18         HD15         I/0 
19        GND                               (20)        Key 
21        (Resv)                              22         GND 
23       -HIOW           I                 24         GND 
25       -HIOR            I                 26         GND 
27        IORDY        O                 28        (Resv) 
29        (Resv)                              30         GND 
31        HIRQ           O                 32         -HIOCS16      O 
33        HA01            I                  34         -PDIAG       I/O 
35        HA00            I                  36         HA02             I
37       -HCSO          I                   38         -HCS1            I 
39       -DASP         I/O                 40         GND 

Note: 

"O" designates an output from the Drive. "I" designates an input to the Drive. 
"I/O" designates an input/output common. 
"PWR" designates a power supply to the Drive. 
"(Resv)" designates reserved pins and all of these have to be left unconnected.

Cabling

The maximum cable length from the Host system to the drive, plus the circuit pattern length inside
the Host systems, must not exceed 18 inches (45.7cm).

Interface 

This data sheet describes some aspects of the host interface to ATA drives. The interface
conforms to the CAM draft proposal for an AT attachment with certain limitations described
below.

Automatic Power-Down Sequence 

A hard reset will disable the automatic power-down sequence.

Format Track Alternate Sectors 

The Drive does not support alternate sector locations and will ignore any descriptors whose
values are 20h (Unassign Alternate Sector) or 40h (Assign Alternate Sector), without returning an
error.

Format Track Interleave Factor

Summary of Contents for WDA L160

Page 1: ...actuator lock Dedicated head landing zone Average seek time 16mS All axis 6 directions mounting permitted Performance Media Read Write Data Transfer rate in Mbits Sec 13 3 Seek times in mS averaged in...

Page 2: ...of the PC at a designated set of mounting holes Other electrical contact may degrade error rate performance As a result of this it is recommended that there should be no metal contact to the hard disk...

Page 3: ...Heads 2 4 Numbers of Disks 1 2 Logical Layout Logical Heads 10 10 Sectors Track 17 34 Logical Cylinders 984 984 Operating Environment Humidity Operating Relative 8 to 90 noncondensing Nonoperating Rel...

Page 4: ...peak acceleration for 15 minutes Operating Shock The Drive will withstand with no permanent damage or loss of data a 10G half sine wave shock pulse of 11mS duration Nonoperating Shock The Drive will w...

Page 5: ...rved pins and all of these have to be left unconnected Cabling The maximum cable length from the Host system to the drive plus the circuit pattern length inside the Host systems must not exceed 18 inc...

Page 6: ...nly in effect until the next power off soft reset or hard reset operation Afterwards the default parameters in the Identify Drive information will be in effect Seek Overlap The drive will wait for the...

Page 7: ...mands are supported by the Drive Data In Commands HEX Identify Drive EC Read Buffer E4 Read Long retry 22 Read Long no retry 23 Read Multiple C4 Read Sectors retry 20 Read Sectors no retry 21 Data Out...

Page 8: ...ta Dimensions Height 19 9 0 4mm Width 101 6 0 4mm Depth 146 0 0 6mm Weight 410g maximum Mounting Orientation The drive can be mounted in any axis 6 directions Note Maximum screw lengths must not be ex...

Page 9: ...shipping container This data sheet is not a substitute for the full product specification which should be used when detailed information is required Product Description data represents IBM s design o...