IBM WDA L160 Manual Download Page 3

IOCHRDY is set to on (ie, jumper on pins 1-2) 
Device ID is set to Master (ie, jumper on pins 3-4) 

Note: 

 LED connections, pin 13 can source up to 18mA. Pin 14 can sink up to 100mA.

Data Organization

Physical Layout      

          WDA-L80          WDA-L160 

Bytes per Sector                     512                      512 
Total Data Sectors              167301                334602 
Total Data Bytes               85,658,112       171,316,224 
BIOS Capacity of Drive (MB {sectors x 512})    

             *                         * 

Sectors per Track                    44                       44 
Sectors per Cylinder                87                     174 
Spare Sectors per Cylinder       1                        2 
Numbers of Data Heads           2                        4 
Numbers of Disks                    1                        2

Logical Layout 

Logical Heads                        10                      10
Sectors/Track                         17                      34 
Logical Cylinders                  984                   984

Operating Environment 

Humidity 

Operating Relative            8% to 90% noncondensing
 Nonoperating Relative     5% to 95% noncondensing

Wet Bulb Temperature: 

Maximum Wet Bulb: 
Operating                       29.4 degrees Centigrade non-condensing 
Non-operating                35.0 degrees Centigrade non-condensing

Elevation: 

Operating Altitude         -150 to 3000m 
Ship/Storage Altitude     -150 to 12000m

Temperature:

Operating                        5 to 55 degrees Centigrade 
Storage                          -40 to 65 degrees Centigrade 
Shipping                        -40 to 65 degrees Centigrade 
Temperature Gradient    15 degrees Centigrade per hour (maximum)
 (Operating, Storage and Shipping)

Summary of Contents for WDA L160

Page 1: ...actuator lock Dedicated head landing zone Average seek time 16mS All axis 6 directions mounting permitted Performance Media Read Write Data Transfer rate in Mbits Sec 13 3 Seek times in mS averaged in...

Page 2: ...of the PC at a designated set of mounting holes Other electrical contact may degrade error rate performance As a result of this it is recommended that there should be no metal contact to the hard disk...

Page 3: ...Heads 2 4 Numbers of Disks 1 2 Logical Layout Logical Heads 10 10 Sectors Track 17 34 Logical Cylinders 984 984 Operating Environment Humidity Operating Relative 8 to 90 noncondensing Nonoperating Rel...

Page 4: ...peak acceleration for 15 minutes Operating Shock The Drive will withstand with no permanent damage or loss of data a 10G half sine wave shock pulse of 11mS duration Nonoperating Shock The Drive will w...

Page 5: ...rved pins and all of these have to be left unconnected Cabling The maximum cable length from the Host system to the drive plus the circuit pattern length inside the Host systems must not exceed 18 inc...

Page 6: ...nly in effect until the next power off soft reset or hard reset operation Afterwards the default parameters in the Identify Drive information will be in effect Seek Overlap The drive will wait for the...

Page 7: ...mands are supported by the Drive Data In Commands HEX Identify Drive EC Read Buffer E4 Read Long retry 22 Read Long no retry 23 Read Multiple C4 Read Sectors retry 20 Read Sectors no retry 21 Data Out...

Page 8: ...ta Dimensions Height 19 9 0 4mm Width 101 6 0 4mm Depth 146 0 0 6mm Weight 410g maximum Mounting Orientation The drive can be mounted in any axis 6 directions Note Maximum screw lengths must not be ex...

Page 9: ...shipping container This data sheet is not a substitute for the full product specification which should be used when detailed information is required Product Description data represents IBM s design o...