IBM WDA L160 Manual Download Page 1

                   IBM OEM STORAGE PRODUCTS                  

      WDA L80 & L160

FEATURES 

 85/171MB formatted capacity (512 bytes/sector)
AT standard interface- Integrated controller
1:1 interleave
1,7 Run-Length Limited (RLL) encoding
32KB Read Look-Ahead Buffer
Self diagnostics on power up
Automatic retry and data correction on read errors
No preventative maintenance required
Media data transfer rate:  13.3 Mbits/Sec
Closed loop actuator servo (embedded sector servo)
Rotary voice coil actuator
Automatic actuator lock
Dedicated head landing zone
Average seek time =    16mS
All axis (6 directions) mounting permitted

Performance  

Media Read/Write 
Data Transfer rate in Mbits/Sec.                      13.3
Seek times (in mS, averaged & inc. settle)
                                                                        Read       Write                                                      
         Track to Track                                              4.0          5.0 
    Average Length                                          16.0         18.5
    Full Length                                                 30.0         32.5 
Spindle Speed                                                 3600 RPM    
    Average Latency                                         8.33 mS 
Power On to Drive Ready                              10 Sec (ave), 31 Sec (max) 
Power Off to Spindle Stop                               6 Sec (ave), 12 Sec (max)

Connectors 

There is a choice of 2 power connections to this drive.  One DC power connector is designed to
mate with AMP part 1-480424 (using AMP pins PN 350078-4).  The other (3-pin) DC power

Pin#   1    2     3    4

      +5V GND GND +12V

1     2     3

+5V +12V GND

Summary of Contents for WDA L160

Page 1: ...actuator lock Dedicated head landing zone Average seek time 16mS All axis 6 directions mounting permitted Performance Media Read Write Data Transfer rate in Mbits Sec 13 3 Seek times in mS averaged in...

Page 2: ...of the PC at a designated set of mounting holes Other electrical contact may degrade error rate performance As a result of this it is recommended that there should be no metal contact to the hard disk...

Page 3: ...Heads 2 4 Numbers of Disks 1 2 Logical Layout Logical Heads 10 10 Sectors Track 17 34 Logical Cylinders 984 984 Operating Environment Humidity Operating Relative 8 to 90 noncondensing Nonoperating Rel...

Page 4: ...peak acceleration for 15 minutes Operating Shock The Drive will withstand with no permanent damage or loss of data a 10G half sine wave shock pulse of 11mS duration Nonoperating Shock The Drive will w...

Page 5: ...rved pins and all of these have to be left unconnected Cabling The maximum cable length from the Host system to the drive plus the circuit pattern length inside the Host systems must not exceed 18 inc...

Page 6: ...nly in effect until the next power off soft reset or hard reset operation Afterwards the default parameters in the Identify Drive information will be in effect Seek Overlap The drive will wait for the...

Page 7: ...mands are supported by the Drive Data In Commands HEX Identify Drive EC Read Buffer E4 Read Long retry 22 Read Long no retry 23 Read Multiple C4 Read Sectors retry 20 Read Sectors no retry 21 Data Out...

Page 8: ...ta Dimensions Height 19 9 0 4mm Width 101 6 0 4mm Depth 146 0 0 6mm Weight 410g maximum Mounting Orientation The drive can be mounted in any axis 6 directions Note Maximum screw lengths must not be ex...

Page 9: ...shipping container This data sheet is not a substitute for the full product specification which should be used when detailed information is required Product Description data represents IBM s design o...