The two controllers are automatically synchronized when you replace a failed
controller. The storage-management software automatically synchronizes the
firmware between the existing controller and the new controller.
Replacing a failed controller
When instructed by the storage-management software, replace a controller CRU by
using the following procedure.
Attention:
After replacing a controller, always use the storage-management
software to verify the firmware levels.
1. Remove the FAStT900 Storage Server bezel, as shown in Figure 21 on
page 16.
Attention:
Removing a controller that is operating normally (not failed) can
result in data loss. Only remove a controller that:
v
Has a fault indicator light that is lit
v
Is marked as “Failed” (offline) through the storage-management software
2. Using Figure 34 as a guide, remove the controller that has failed.
a. Using your thumbs, squeeze the two center tabs and pull both controller
handles outward with your fingers.
b. Using both handles, pull out on the controller to remove it.
Attention:
When you handle static-sensitive devices, take precautions to
avoid damage from static electricity. For details about handling static-sensitive
devices, see “Handling static-sensitive devices” on page 37.
3. Unpack the new controller. Using the proper handling precautions, remove the
new controller from the packing material.
Check the shipping invoice and the controller to make sure that it has the same
memory size as the controller that you just removed.
4. Using Figure 34 as a guide, install the new controller as follows:
a. Using your thumbs, squeeze the two center tabs and pull both controller
handles outward with your fingers.
Figure 34. Removing and replacing a failed controller CRU
Chapter 3. Replacing the FAStT900 Storage Server components
39
Summary of Contents for TotalStorageFAStT900
Page 2: ......
Page 3: ...IBM TotalStorageFAStT900 Fibre Channel Storage Server User s Guide GC26 7534 00 ...
Page 7: ...IBM license agreement for Machine Code 70 Glossary 71 Index 79 Contents v ...
Page 8: ...vi IBM TotalStorageFAStT900 Fibre Channel Storage Server User s Guide ...
Page 10: ...viii IBM TotalStorageFAStT900 Fibre Channel Storage Server User s Guide ...
Page 12: ...x IBM TotalStorageFAStT900 Fibre Channel Storage Server User s Guide ...
Page 18: ...xvi IBM TotalStorageFAStT900 Fibre Channel Storage Server User s Guide ...
Page 62: ...36 IBM TotalStorageFAStT900 Fibre Channel Storage Server User s Guide ...
Page 86: ...60 IBM TotalStorageFAStT900 Fibre Channel Storage Server User s Guide ...
Page 108: ...82 IBM TotalStorageFAStT900 Fibre Channel Storage Server User s Guide ...
Page 111: ......
Page 112: ... Part Number 32P0341 Printed in U S A GC26 7534 00 1P P N 32P0341 ...