![IBM TotalStorageFAStT900 User Manual Download Page 41](http://html.mh-extra.com/html/ibm/totalstoragefastt900/totalstoragefastt900_user-manual_607849041.webp)
Chapter 2. Operating the FAStT900 Storage Server
This chapter describes the tasks required to operate the FAStT900 Storage Server.
Tasks overview
Perform the tasks shown in Table 5 to maintain the FAStT900 Storage Server after
you install it.
Table 5. Tasks overview
Task
Description
See
Accessing the FAStT900 Storage
Server components and indicator
lights
To access the controller CRUs,
battery, storage server fan, and
indicator lights, remove the FAStT900
Storage Server bezel.
“Removing and replacing the front
bezel to access the FAStT Storage
Server components” on page 16
Turning on or off the power
The FAStT900 Storage Server usually
runs continuously. However, you might
need to turn off the power to move the
FAStT900 Storage Server or to
perform maintenance procedures.
“Turning on the power” on page 17
and “Turning off the power” on
page 18
Monitoring FAStT900 Storage Server
status through software
Run the storage-management
software continuously. This software
checks the storage subsystem for
failures and displays messages that
indicate the types of failures and the
recovery procedures.
“Monitoring status through software”
on page 20
Checking fault indicator lights for
component failures
Component failures are indicated by
lights on the front and back of the
FAStT900 Storage Server and are
monitored by the
storage-management software.
Note:
The indicator lights identify
problems with the FAStT900 Storage
Server components, but you might
need more information to thoroughly
diagnose and repair the unit.
Therefore, it is important to use the
storage-management software to
continuously monitor the status of the
FAStT900 Storage Server.
“Checking the indicator lights” on
page 20
Restoring power after a power supply
shutdown
When the FAStT900 Storage Server
shuts down because of a power
supply overtemperature condition,
take special care restarting it.
“Overtemperature condition and power
supply shutdown” on page 31
Checking the battery service date
Periodically check the battery service
date information. Replace the battery
whenever it fails to hold a charge or
every three years.
Note:
Using the FAStT900 Storage
Server in a hot environment (above
35° C or 95° F), lowers the battery life
expectancy. Environmental conditions
that are not in the specified range are
not supported.
“Checking the battery service date” on
page 32
© Copyright IBM Corp. 2001, 2003
15
Summary of Contents for TotalStorageFAStT900
Page 2: ......
Page 3: ...IBM TotalStorageFAStT900 Fibre Channel Storage Server User s Guide GC26 7534 00 ...
Page 7: ...IBM license agreement for Machine Code 70 Glossary 71 Index 79 Contents v ...
Page 8: ...vi IBM TotalStorageFAStT900 Fibre Channel Storage Server User s Guide ...
Page 10: ...viii IBM TotalStorageFAStT900 Fibre Channel Storage Server User s Guide ...
Page 12: ...x IBM TotalStorageFAStT900 Fibre Channel Storage Server User s Guide ...
Page 18: ...xvi IBM TotalStorageFAStT900 Fibre Channel Storage Server User s Guide ...
Page 62: ...36 IBM TotalStorageFAStT900 Fibre Channel Storage Server User s Guide ...
Page 86: ...60 IBM TotalStorageFAStT900 Fibre Channel Storage Server User s Guide ...
Page 108: ...82 IBM TotalStorageFAStT900 Fibre Channel Storage Server User s Guide ...
Page 111: ......