IBM TotalStorage Ultrium Tape Drive 3580

Models L23 and H23

Setup and Operator Guide

GA32-0460-00

Summary of Contents for TotalStorage Ultrium 3580 H23

Page 1: ...IBM TotalStorage Ultrium Tape Drive 3580 Models L23 and H23 Setup and Operator Guide GA32 0460 00...

Page 2: ......

Page 3: ...IBM TotalStorage Ultrium Tape Drive 3580 Models L23 and H23 Setup and Operator Guide GA32 0460 00...

Page 4: ...age lto First Edition February 2003 This edition applies to the IBM TotalStorage Ultrium Tape Drive 3580 Models L23 and H23 Setup and Operator Guide and to all subsequent releases and modifications un...

Page 5: ...nes for Using Bar Code Labels 29 Setting the Write Protect Switch 30 Handling the Cartridges 30 Provide Training 30 Ensure Proper Packaging 31 Provide Proper Acclimation and Environmental Conditions 3...

Page 6: ...he Rack 101 Appendix E TapeAlert Flags 103 Appendix F Power Cords 105 Power Cable Information 105 Types of Receptacles 107 Appendix G Parts List 109 Parts for 3580 Ultrium 2 Tape Drive Model L23 109 P...

Page 7: ...moving the C clip from the leader pin 39 20 Attaching the leader pin to the tape 40 21 Flowchart for analyzing maintenance problems 47 22 Checking the setting on the SCSI address switch 48 23 Componen...

Page 8: ...vi IBM 3580 Ultrium Tape Drive Setup and Operator Guide...

Page 9: ...TO Ultrium Tape Cartridge 42 6 Ordering media supplies for the 3580 Ultrium 2 Tape Drive 44 7 Authorized suppliers of custom bar code labels 45 8 Codes on the single character display of the 3580 Ultr...

Page 10: ...viii IBM 3580 Ultrium Tape Drive Setup and Operator Guide...

Page 11: ...follows DANGER An electrical outlet that is not correctly wired could place hazardous voltage on metal parts of the system or the products that attach to the system It is the customer s responsibilit...

Page 12: ...CAUTION Do not attempt to use the handle on the module to lift the entire device module and enclosure as a unit First remove the module then use two hands to lift the enclosure 72XXC356 CAUTION This p...

Page 13: ...Check the tape drive s power cord for damage such as a pinched cut or frayed cord 6 Check the tape drive s SCSI bus signal cable for damage 7 Check the cover of the tape drive for sharp edges damage o...

Page 14: ...xii IBM 3580 Ultrium Tape Drive Setup and Operator Guide...

Page 15: ...shipping them It also tells how to handle the cartridges how to set a cartridge s write protect switch and how to order additional cartridges Chapter 5 Troubleshooting on page 47 gives tips for solvin...

Page 16: ...instructions for attaching IBM supported hardware to open systems operating systems It indicates what devices and levels of operating systems are supported gives the requirements for adapter cards an...

Page 17: ...MB per second at 2 1 compression 2 v Burst data transfer rate of 160 MB per second for Model L23 The IBM 3580 Tape Drive Models L23 and H23 are equipped internally with the IBM Ultrium 2 Tape Drive Fo...

Page 18: ...2 media 30 MB s 40 MB s with Ultrium 1 media Maximum sustained data rate at maximum compression 107 MB s Ultra160 60 MB s Burst data rate for Low Voltage Differential LVD SCSI drives 160 MB s Ultra16...

Page 19: ...t have Internet access and you need information about device drivers contact your Marketing Representative v Using a browser type one of the following http www ibm com storage lto select either Techni...

Page 20: ...e Drive Physical Specifications Specification Dimensions Width 17 1 cm 6 74 in Length 33 3 cm 13 11 in Height 14 6 cm 5 75 in Weight 6 59 kg 14 3 lbs Power Specifications AC line voltage 100 to 240 Va...

Page 21: ...can purchase installation services by contacting your local IBM Service office or your IBM Business Partner To install the 3580 Ultrium 2 Tape Drive complete the following steps DANGER An electrical o...

Page 22: ...Quick Reference GX35 5068 __ 9 The IBM TotalStorage Ultrium Tape Drive 3580 Models L23 and H23 Setup and Operator Guide GA32 0460 this guide __ 10 The IBM Externally Attached Devices Safety Informatio...

Page 23: ...tch 3 Single character display 9 SCSI address switch 4 Status light 10 Machine type model number and serial number 5 Unload button 11 IBM Repair Identification Tag Placeholder 6 External SCSI connecto...

Page 24: ...or push button until the ID that you want displays on the switch Note If the SCSI ID is changed after installation cycle the power turn it off then on again to activate the new SCSI ID Step 6 Position...

Page 25: ...segments and then goes blank At the outset of the POST the following message appears in the message display for 90 seconds Power On Self Test In Progress v If the test succeeds the following message...

Page 26: ...t the desired code press the unload button once per second until the code redisplays Maint Mode Select Fast R W Diagnostic __ 5 Press and hold the unload button for 2 or more seconds then release it t...

Page 27: ...r status light turns off and the following message displays Passed Tape Unloading followed by Cartridge Unloading In Progress then Ultrium Tape Drive Drive Empty v If an error is detected the status l...

Page 28: ...instructions on downloading the latest device drivers the CD contains device drivers current at time of manufacturing Install device drivers for the 3580 Ultrium 2 Tape Drive as follows Note If you in...

Page 29: ...he electrical outlet __ 2 If the server s SCSI bus is in operation stop all activity on the bus that you are connecting to for instructions about how to stop SCSI bus activity see your server s docume...

Page 30: ...ly Device On the SCSI Bus connect the SCSI bus cable to the server see Figure 3 1 3580 Ultrium 2 Tape Drive 5 SCSI host adapter card 2 SCSI connectors 6 Server 3 Terminator 4 SCSI bus cable Figure 3 E...

Page 31: ...LVD or HVD DIFF SCSI interface see Step 9 Installing the SCSI Host Adapter Card if required on page 12 Attention Do not mix LVD and HVD DIFF SCSI host adapters tape drives or terminators on the same b...

Page 32: ...16 IBM 3580 Ultrium Tape Drive Setup and Operator Guide...

Page 33: ...e primary electrical power within the enclosure is still active If you do not want electrical power to be present in the enclosure unplug the 3580 Ultrium 2 Tape Drive s power cord from the receptacle...

Page 34: ...or more information see Performing a Diagnostic or Maintenance Function on page 62 v Perform a panic reset of the drive Attention If you press the Unload button during host operation the 3580 Ultrium...

Page 35: ...he tape the process may take approximately 13 minutes The light stops blinking and becomes solid when the drive completes the recovery and is ready for a read or write operation To eject the cartridge...

Page 36: ...itions and informational messages If multiple errors occur the code with the highest priority represented by the lowest number displays first When the error is corrected the code with the next highest...

Page 37: ...e write protect switch so that data cannot be written to it the message reads as follows where WP equals write protect Volume Loaded DC WP Ready Removing a Tape Cartridge Attention Remove any cartridg...

Page 38: ...endix B Performing Diagnostic and Maintenance Functions on page 59 Updating the Drive Firmware Attention To ensure optimum performance from the 3580 Ultrium 2 Tape Drive use the latest level of drive...

Page 39: ...e cleaning cycle takes less than 2 minutes When the cleaning is finished the drive ejects the cartridge Note If you insert a cleaning cartridge when the drive does not need to be cleaned or if you ins...

Page 40: ...24 IBM 3580 Ultrium Tape Drive Setup and Operator Guide...

Page 41: ...rtridge s volume serial number VOLSER indicates the generation of the media For example a cartridge with a VOLSER of 000764L2 is an Ultrium 2 cartridge a cartridge with a VOLSER of 003995L1 is an Ultr...

Page 42: ...ull or until all data is written Both generations of the IBM LTO Ultrium Data Cartridges include a Linear Tape Open Cartridge Memory LTO CM chip 1 in Figure 7 on page 25 that contains information abou...

Page 43: ...erts you by displaying C on the single character display To clean the head insert the IBM LTO Cleaning Cartridge into the tape load compartment see Figure 6 on page 21 The tape drive performs the clea...

Page 44: ...idges with the labels included or you can order custom labels To order tape cartridges and bar code labels see Ordering Media Supplies on page 43 The bar code for usage in IBM tape libraries must meet...

Page 45: ...printed characters or bar code a library s inventory operation will take much longer if the bar code label is not readable v Remove the label from the label sheet carefully Do not stretch the label o...

Page 46: ...st manually set the write protect switch slide it left or right to the desired position Handling the Cartridges Attention Do not insert a damaged tape cartridge into your 3580 Ultrium 2 Tape Drive A d...

Page 47: ...ontainer that securely holds the cartridge in its jewel case during transportation Ultrium Turtlecases by Perm A Store have been tested and found to be satisfactory see Figure 10 They are available at...

Page 48: ...on page 42 Perform a Thorough Inspection After purchasing a cartridge and before using it perform the following steps v Inspect the cartridge s packaging to determine potential rough handling v When i...

Page 49: ...rly seated in the pin retaining spring clips see 2 in Figure 13 on page 35 If the leader pin has become dislodged go to Repositioning or Reattaching a Leader Pin on page 35 v Do not handle tape that i...

Page 50: ...eader Pin on page 35 Then immediately use data recovery procedures to minimize chances of data loss 3 Review media handling procedures Example Improper Placement of Leader Pin see Figure 13 on page 35...

Page 51: ...must remove more than 7 meters 23 feet of leader tape The sections that follow describe each procedure Repositioning a Leader Pin A leader pin that is improperly seated inside a cartridge can interfer...

Page 52: ...door 5 To rewind the tape insert the cartridge manual rewind tool 1 in Figure 15 into the cartridge s hub 2 and turn it clockwise until the tape becomes taut 6 Remove the rewind tool by pulling it awa...

Page 53: ...s see 3 in Figure 16 Leader pins and C clips Attention v Use only the IBM Leader Pin Reattachment Kit to reattach the leader pin to the tape Other methods of reattaching the pin will damage the tape t...

Page 54: ...he cartridge 2 so that the tool s hook 3 latches into the cartridge s door 4 Pull the tool back to hold the door open then slide the tool onto the cartridge Open the tool s pivot arm 5 Figure 17 Attac...

Page 55: ...t from the cartridge 4 Remove the rewind tool by pulling it away from the cartridge Set the tool and the cartridge aside 5 On the leader pin 1 in Figure 19 locate the open side of the C clip 2 The C c...

Page 56: ...pe over the leader pin and hold it with your fingers see Figure 20 Note Use care to ensure that the tape is centered over the leader pin Failure to properly center the tape on the pin will cause the r...

Page 57: ...ader pin is latched by the pin retaining spring clips on each end of the leader pin 15 Remove the rewind tool 16 Remove the leader pin attach tool by lifting its end up and away from the cartridge Att...

Page 58: ...inants and physical damage Ship the cartridge in a shipping container that has enough packing material to cushion the cartridge and prevent it from moving within the container Table 5 gives the enviro...

Page 59: ...em before you dispose of a cartridge Contact your account representative for information about the materials that are in the cartridge If a tape cartridge must be disposed of in a secure manner you ca...

Page 60: ...rized IBM Business Partner or your IBM Sales Representative by specifying Machine Type 3589 Model 003 v Call 1 888 IBM MEDIA IBM LTO Ultrium 100 GB Data Cartridge with bar code label Bar code labels a...

Page 61: ...ephone 800 522 3528 http www colorflex com Ai Home asp EDP Europe Ltd 43 Redhills Road South Woodham Ferrers Chelmsford Essex CM3 5UL U K Telephone 44 0 1245 322380 http www edpeurope com media_labell...

Page 62: ...46 IBM 3580 Ultrium Tape Drive Setup and Operator Guide...

Page 63: ...the single character display see Appendix A Codes on the Single Character Display on page 55 Should the drive need to be replaced go to Replacing the Tape Drive on page 52 Please review the pre call c...

Page 64: ...that the ID is not one that is used by another device or the SCSI host adapter note that because ID 7 is the highest priority ID on the SCSI bus it is usually reserved for the primary SCSI host adapte...

Page 65: ...ther the parameters for the SCSI adapter installation are correct 3 Ensure that a SCSI terminator is attached to each end of the bus one terminator is usually installed at the server 4 Ensure that no...

Page 66: ...Tape Drive perform the following steps before you place a call to IBM Technical Support Where instructions refer you to the web visit http www ibm com storage lto __ 1 Verify that the drive s firmwar...

Page 67: ...them To halt the diagnostics press the unload button The diagnostics will continue to the end of the loop and then stop The drive then exits maintenance mode Chapter 5 Troubleshooting 51...

Page 68: ...gure 23 on page 53 3 Write down the serial number of the failed drive on the repair tag 4 Affix the repair tag to the replacement drive near to but not covering the serial number on the drive 5 Place...

Page 69: ...r display 9 SCSI address switch 4 Status light 10 Machine type model number and serial number 5 Unload button 11 IBM Repair Identification Tag Instructions 6 External SCSI connectors 12 IBM Repair Ide...

Page 70: ...54 IBM 3580 Ultrium Tape Drive Setup and Operator Guide...

Page 71: ...ooling problem The tape drive detected that the recommended operating temperature was exceeded Perform one or more of the following actions v Ensure that the cooling fan is rotating and is quiet If no...

Page 72: ...drive determined that a firmware or tape drive hardware failure occurred Perform the following action 1 Collect a drive dump from one of the following Note Do not force a new dump one already exists...

Page 73: ...ostics fail replace the tape drive v If the diagnostics succeed run the Test Head diagnostic see Function Code H in Table 9 on page 59 If the Test Head diagnostic fails replace the tape drive If the T...

Page 74: ...SI bus See Procedure 3 on page 49 The error code clears 10 seconds after the drive detected the error or when you place the drive in maintenance mode 9 Tape drive or RS 422 error The tape drive determ...

Page 75: ...m 2 Tape Drive to copy its field microcode replacement FMR data to a scratch blank data cartridge 3 Page 65 Force a Drive Dump Causes the 3580 Ultrium 2 Tape Drive to perform a dump of data also known...

Page 76: ...sts to ensure that a suspect cartridge and its magnetic tape are acceptable E Page 75 Fast Read Write Test Causes the 3580 Ultrium 2 Tape Drive to perform tests to ensure that the drive can read from...

Page 77: ...The status light becomes solid amber 0 appears in the single character display and the following message displays indicating that the tape drive is in maintenance mode Maint Mode Select Exit Maint Mo...

Page 78: ...us light becomes solid amber and the following message displays indicating that the tape drive is in maintenance mode Maint Mode Select Exit Maint Mode Note If a cartridge is in the tape drive it will...

Page 79: ...ngle character display The drive rewinds and unloads the cartridge and then exits maintenance mode The solid amber status light turns off and the following message displays Passed Tape Unloading follo...

Page 80: ...ject the first time that you press the unload button and the drive will not be placed in maintenance mode To continue placing the drive in maintenance mode perform the preceding step 4 Press the unloa...

Page 81: ...FMR tape exits maintenance mode and displays the following message Ultrium Tape Drive Drive Empty Contact IBM Technical Support for problem determination or machine replacement Function Code 3 Create...

Page 82: ...rt a scratch blank data cartridge that is not write protected or the tape drive exits maintenance mode Create FMR Tape Load Scratch Tape After you insert the scratch data cartridge the flashing C in t...

Page 83: ...cating that the tape drive is in maintenance mode Maint Mode Select Exit Maint Mode Note If a cartridge is in the tape drive it will eject the first time that you press the unload button and the drive...

Page 84: ...following message displays indicating that the tape drive is in maintenance mode Maint Mode Select Exit Maint Mode Note If a cartridge is in the tape drive it will eject the first time that you press...

Page 85: ...ERROR Cooling Problem To determine the error locate the code in Table 8 on page 55 The tape drive unloads the tape cartridge exits maintenance mode and displays the following message Ultrium Tape Dri...

Page 86: ...at the rear of the 3580 Ultrium 2 Tape Drive 6 Make sure that the 3580 Ultrium 2 Tape Drive is terminated at one of its SCSI connectors or at the SCSI bus 7 Press and hold the unload button for 3 or...

Page 87: ...To determine the error locate 8 in Table 8 on page 55 To clear the error turn the power off then on again Appendix B Diagnostic and Maintenance Functions 71...

Page 88: ...tape drive it will eject the first time that you press the unload button and the drive will not be placed in maintenance mode To continue placing the drive in maintenance mode perform the preceding s...

Page 89: ...the log 0 displays on the single character display 1 Make sure that no cartridge is in the drive 2 Make sure that the following message appears on the message display you may need to turn the power o...

Page 90: ...tape drive exits maintenance mode and the following message displays Display Err Log Exit Maint Mode followed by Ultrium Tape Drive Drive Empty Function Code A Clear Error Code Log Function Code A era...

Page 91: ...tests that determine whether a suspect cartridge and its magnetic tape are acceptable The diagnostic takes approximately 15 minutes to complete and loops continually until you halt it To halt the diag...

Page 92: ...Media Load Scratch Tape After you insert the cartridge the flashing C in the single character display changes to E and one or more of the following messages display Test Media Tape Loading Test Media...

Page 93: ...1 Attention For this test insert only a scratch blank data cartridge or a cartridge that may be overwritten During the test the drive overwrites the data on the cartridge 1 Make sure that no cartridge...

Page 94: ...ng followed by Fast R W Diagnostic Writing and Fast R W Diagnostic Reading The tape drive runs the tests Note If you inserted an invalid or write protected tape cartridge 7 appears in the single chara...

Page 95: ...ll continue to the end of its loop then stop The drive then exits maintenance mode Attention For this test insert only a scratch blank data cartridge or a cartridge that may be overwritten During the...

Page 96: ...racter display changes to H and one or more of the following messages display Test Head Tape Loading Test Head Locating Test Head Rewinding followed by Test Head Writing The tape drive runs the tests...

Page 97: ...hange to P for 1 5 sec and then exit maintenance mode Default is NOT enabled Function Code 0 Exit Maintenance Mode Function Code 0 makes the 3580 Ultrium 2 Tape Drive available for reading and writing...

Page 98: ...is detected the single character display shows an error code but still exits maintenance mode To determine the error locate the code in Table 8 on page 55 To clear the error turn the power off then o...

Page 99: ...do so however requires care Success depends on your ability to maintain constant and appropriate tension on the tape while rewinding it into the cartridge and disengaging it from the drive s leader bl...

Page 100: ...to perform this procedure it could destroy the tape v Never touch the head or electronic components within the 3580 Ultrium 2 Tape Drive Touching may cause contamination or damage by electrostatic di...

Page 101: ...k of the unit to determine the location of the SCSI connectors see Figure 2 on page 7 3 Place the 3580 Ultrium 2 Tape Drive on its side and locate the access hole at the bottom of the unit see 1 in Fi...

Page 102: ...open the door of the tape load compartment 2 and locate the black flag 3 on the cartridge s takeup reel The flag is positioned behind the tape cartridge and near the rear of the drive 7 To ensure that...

Page 103: ...with the allen wrench 2 rotate the loader motor gear with the small blade screwdriver in a counterclockwise direction see arrow The rotation of the loader motor gear causes the leader pin block to mov...

Page 104: ...tment 2 Remove the tape cartridge 3 To reuse the 3580 Ultrium 2 Tape Drive you must raise the drive s loader so that it is able to accept a cartridge To raise the loader continue to wind the loader mo...

Page 105: ...e Internal Drive 1 Remove the cover see 1 in Figure 27 of the 3580 Ultrium 2 Tape Drive by performing the following steps a Place the 3580 Ultrium 2 Tape Drive on its side and use a Phillips screwdriv...

Page 106: ...3 from the front panel display board by pulling it away from the connector b Remove the internal RS 422 cable 4 from the front panel display board by pulling it away from the connector a67s0142 0 1 2...

Page 107: ...one at the front of the 3580 Ultrium 2 Tape Drive and one at the front of the internal tape drive d Remove the 3580 Ultrium 2 Tape Drive s bezel 2 by lifting the unit up and away from the bezel Set t...

Page 108: ...ling it away from the drive j Remove the internal SCSI address cable 6 by pulling it away from the drive k Gently remove the internal RS 422 cable 7 by grasping its wires and pulling straight back tow...

Page 109: ...ide as shown in Figure 32 on page 94 2 Examine the tape to determine the source of the problem v If the leader pin is jammed in the cartridge go to the Note contained in step 4 on page 94 v If the lea...

Page 110: ...wise 2 to wind the excess tape into the cartridge Guide the leader pin toward the cartridge and drop it deep inside the cartridge door do not attempt to seat the leader pin Remove the allen wrench Not...

Page 111: ...the unload direction guide the end of the leader pin block 5 into the white block guide 6 4 Continue to rotate the loader motor gear counterclockwise until you feel resistance and the cartridge eject...

Page 112: ...ltrium 2 Tape Drive reverse the preceding steps After you remove the stuck tape cartridge copy the data on the tape to another tape Then discard the stuck tape cartridge 96 IBM 3580 Ultrium Tape Drive...

Page 113: ...nsure that a hazardous condition is not created due to uneven mechanical loading when installing this unit in a rack If the rack has a stabilizer it must be firmly attached before installing or removi...

Page 114: ...ar of the rack Make sure that you install the cage nuts at the same level on the two mounting rails a Hook one side of the cage nut clip into the square hole of the rackmount rail b Hold the cage nut...

Page 115: ...ails 8 Hold the shelf level and line up the shelf front flanges with the cage nuts that were installed in step 3 on page 98 9 Insert two screws through the holes in the front flanges Loosely thread th...

Page 116: ...l and line up the threaded holes on the rear of the shelf with the appropriate holes on the rear mounting rails 16 Insert a screw through the holes in each rear mounting rail and loosely thread the sc...

Page 117: ...s toward the rear of the rack Make sure that you install the nuts at the same level on the two mounting rails b Hold the shelf safety bar level across the front of the rack c Line up the holes on the...

Page 118: ...102 IBM 3580 Ultrium Tape Drive Setup and Operator Guide...

Page 119: ...rted by the 3580 Ultrium 2 Tape Drive Flag Number Flag 3 Hard error 4 Media 5 Read failure 6 Write failure 8 Not data grade 9 Write protect 10 No removal 11 Cleaning media 12 Unsupported format 14 Unr...

Page 120: ...104 IBM 3580 Ultrium Tape Drive Setup and Operator Guide...

Page 121: ...ly with the plug standards of the National Electrical Manufacturers Association NEMA For other worldwide geographies plug standards are listed in Table 10 Power Cable Information Table 10 Power cable...

Page 122: ...onaco Morocco Mozambique Netherlands New Caledonia Niger Norway Poland Portugal Reunion Romania Russia Rwanda Sao Tome Senegal Serbia Slovakia Slovenia Somalia Spain Sweden Syria Tajikistan Togo Tunis...

Page 123: ...s Republic of China 12 Note Part number 6952300 is the default power cord for the countries or regions listed If you do not specify a power cord when you place your order IBM provides this power cord...

Page 124: ...108 IBM 3580 Ultrium Tape Drive Setup and Operator Guide...

Page 125: ...le 19P0048 5610 10 m VHDCI HD68 SCSI Cable 19P0049 5620 20 m VHDCI HD68 SCSI Cable 35L1977 5625 25 m VHDCI HD68 SCSI Cable 19P0481 N A LVD single connector SCSI wrap tool 19P0874 N A LVD multi mode te...

Page 126: ...e 19P0048 5610 10 m VHDCI HD68 SCSI Cable 19P0049 5620 20 m VHDCI HD68 SCSI Cable 35L1977 5625 25 m VHDCI HD68 SCSI Cable 19P1213 N A HVD single connector SCSI wrap tool 61G8324 N A HVD multi mode ter...

Page 127: ...h local law INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NO...

Page 128: ...information is for planning purposes only The information herein is subject to change before the products described become available This information contains examples of data and reports used in dai...

Page 129: ...ss Machines Corporation and Seagate Technology v Linear Tape Open v LTO v Ultrium Tape Drive Intel is a registered trademark of Intel Corporation in the United States or other countries or regions or...

Page 130: ...e the equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept a...

Page 131: ...IBM Deutschland Informationssysteme GmbH 70548 Stuttgart Informationen in Hinsicht EMVG Paragraph 3 Abs 2 2 Das Ger t erf llt die Schutzanforderungen nach EN 50082 1 und EN 55022 Klasse A EN 55022 Kl...

Page 132: ...116 IBM 3580 Ultrium Tape Drive Setup and Operator Guide...

Page 133: ...device to identify the cartridge and its volume serial number bit Either of the digits 0 or 1 when used in the binary numbering system browser A client program that initiates requests to a web server...

Page 134: ...from a computer to a connected device typically a personal computer drive See IBM Ultrium 2 Tape Drive or 3580 Ultrium 2 Tape Drive drive dump The recording at a particular instant of the contents of...

Page 135: ...label may be affixed LCD See liquid crystal display leader pin Within the LTO Ultrium Tape Cartridge a small metal column attached to the end of the magnetic tape During tape processing the leader pi...

Page 136: ...ontrast with Model L23 N native data capacity The amount of data that can be stored without compression on a tape cartridge O oersted The unit of magnetic field strength in the unrationalized centimet...

Page 137: ...ymous with SCSI bus cable and SCSI cable SCSI bus cable See SCSI bus SCSI cable See SCSI bus SCSI command An operation performed by a target tape drive for an initiator server The command is initiated...

Page 138: ...able system toggle switch A device that can alternate between two modes track A linear or angled pattern of data written on a tape surface transfer rate See data transfer rate U U Pertaining to the ra...

Page 139: ...text links to other documents available through the network write To make a permanent or transient recording of data in a storage device or on a data medium write protected A tape cartridge is write p...

Page 140: ...124 IBM 3580 Ultrium Tape Drive Setup and Operator Guide...

Page 141: ...7 68 drive performance specifications 2 E ejecting a tape cartridge 21 electronic emissions 114 end of life EOL plan xi environmental notice xi EOL plan xi erasing tape 30 32 error code log displaying...

Page 142: ...ing 12 HVD DIFF signaling system 1 12 LVD signaling system 1 12 wrap test running 59 69 specifications for bar code and bar code label LTO Ultrium Tape Cartridge 28 for media LTO Ultrium Tape Cartridg...

Page 143: ...specification 4 W weight of 3580 Ultrium 2 Tape Drive 4 wet bulb temperature specifications for tape drive 4 width of 3580 Ultrium 2 Tape Drive 4 wrap test running SCSI 59 69 write protect switch loc...

Page 144: ...128 IBM 3580 Ultrium Tape Drive Setup and Operator Guide...

Page 145: ...on in this book is Very Satisfied Satisfied Neutral Dissatisfied Very Dissatisfied Accurate h h h h h Complete h h h h h Easy to find h h h h h Easy to understand h h h h h Well organized h h h h h Ap...

Page 146: ...pment Department GZW 9000 South Rita Road Tucson Arizona U S A 85775 4401 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Page 147: ......

Page 148: ...Part Number 18P7386 Printed in U S A GA32 0460 00 1P P N 18P7386...

Page 149: ...Spine information IBM TotalStorage Ultrium Tape Drive 3580 Models L23 and H23 IBM 3580 Ultrium Tape Drive Setup and Operator Guide...