Note:
Avoid
operating
the
FAStT100
with
controllers
of
different
cache
sizes.
Operating
the
storage
server
with
controllers
of
different
cache
size
will
disable
caching
and
might
adversely
affect
performance.
To
replace
a
RAID
controller,
perform
the
following
steps:
1.
Check
the
Storage
Manager
client
for
instructions
on
RAID
controller
failure-recovery
procedures.
Follow
the
steps
provided
in
the
software
documentation
before
continuing
with
step
2.
2.
Label
each
cable
that
connects
to
the
RAID
controller
that
has
failed.
This
ensures
that
all
cables
will
be
properly
reconnected
to
the
new
RAID
controller.
Attention:
Handle
and
install
fiber-optic
cables
properly
to
avoid
degraded
performance
or
loss
of
communications
with
devices.
When
working
with
fiber-optic
cables,
do
not
pinch
them,
step
on
them,
or
locate
them
in
aisles
or
walkways.
Do
not
overtighten
the
cable
straps
or
bend
the
cables
to
a
radius
smaller
than
38
mm
(1.5
in.).
3.
From
the
RAID
controller
that
has
failed,
remove
the
fibre-channel
cables
from
the
SFPs.
The
location
of
these
components
is
shown
in
After
removing
the
fibre-channel
cables,
insert
the
protective
caps.
4.
Use
the
following
procedure
to
remove
the
SFPs
from
the
RAID
controller
that
has
failed.
a.
Remove
the
LC-LC
fibre-channel
cable
from
the
SFP
module.
For
more
information,
see
b.
Unlock
the
SFP
module
latch:
v
For
SFP
modules
that
contain
plastic
tabs,
unlock
the
SFP
module
latch
by
pulling
the
plastic
tab
outward
10°,
as
shown
in
SFP module
RAID controller
Fiber-optic
cable
f10ug041
Figure
64.
Location
of
SFPs
and
fiber-optic
cables
84
IBM
TotalStorage
FAStT100
Storage
Server:
Installation,
User’s,
and
Maintenance
Guide
Summary of Contents for totalstorage fastt100
Page 2: ......
Page 10: ...viii IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 14: ...xii IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 18: ...xvi IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 30: ...xxviii IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 68: ...38 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 86: ...56 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 124: ...94 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 132: ...102 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 134: ...104 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 138: ...108 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 159: ......
Page 160: ... Part Number 24P8970 Printed in USA GC26 7641 00 1P P N 24P8970 ...