Chapter 4. Adapter operating environment and specifications
This chapter contains the FAStT FC2-133 Adapter operating environment and
specification information.
Table 9. Adapter operating environment
Environment
Minimum
Maximum
Operating temperature
0°C (32°F)
55°C (131°F)
Storage temperature
-20°C (-4°F)
70°C (158°F)
Relative humidity (noncondensing)
10%
90%
Storage humidity (noncondensing)
5%
95%
Table 10. Adapter specifications
Type
Specification
Host bus
Conforms to Intel
PCI Local Bus Specification
, revision 2.2
and the
PCI-X Addendum
, revision 1.0.
PCI/PCI-X signaling
environment
3.3 V and 5.0 V buses supported
PCI/PCI-X transfer rate
v
Support for 32 bit and 64 bit PCI bus at 33 MHz and 64
MHz
v
Support for 64 bit PCI-X bus at 50 MHz, 100 MHz, and
133 MHz
v
PCI transfer rate 264 MB per second maximum burst rate
for 33 MHz operation (ISP2312 chip)
v
Support for dual address bus cycles
Fibre Channel specifications
v
Fiber-optic media (shortwave multimode 50 micron cable)
v
Bus transfer rate: 200 MB per second maximum at
half-duplex and 400 MB per second maximum at
full-duplex.
v
Interface chip: ISP2312 (PCI-X QLA23xx boards)
v
Support for both FCP-SCSI and IP protocols
v
Support for point-to-point fabric connection: F-Port Fabric
Login
v
Support for FCAL public loop profile: FL-Port Login
v
Support for Fibre Channel services class 2 and 3
v
Support for FCP SCSI initiator and target operation
v
Support for full-duplex operation
Processor
Single-chip design that includes a RISC processor, Fibre
Channel protocol manager, PCI or PCI-X DMA controller,
and integrated serializer/deserializer (SERDES) and
electrical transceivers that can auto-negotiate a data rate of
2 GB per second.
Host data transfer
64-bit, bus-master DMA data transfers to 1056 MB per
second
RAM
RAM 256 KB of SRAM supporting parity protection
BIOS ROM
BIOS ROM 128 KB of flash ROM in two 64 KB, software
selectable banks. The flash is field programmable.
NVRAM
NVRAM 256 bytes, field programmable
© Copyright IBM Corp. 2002
23
Summary of Contents for TotalStorage FAStT FC2-133
Page 1: ...IBM IBM TotalStorage FAStT FC2 133 Host Bus Adapter Installation and User s Guide...
Page 2: ......
Page 3: ...IBM TotalStorage FAStT FC2 133 Host Bus Adapter Installation and User s Guide...
Page 8: ...vi IBM TotalStorage FAStT FC2 133 Host Bus Adapter Installation and User s Guide...
Page 12: ...x IBM TotalStorage FAStT FC2 133 Host Bus Adapter Installation and User s Guide...
Page 22: ...8 IBM TotalStorage FAStT FC2 133 Host Bus Adapter Installation and User s Guide...
Page 54: ...40 IBM TotalStorage FAStT FC2 133 Host Bus Adapter Installation and User s Guide...
Page 60: ...46 IBM TotalStorage FAStT FC2 133 Host Bus Adapter Installation and User s Guide...
Page 63: ......
Page 64: ...Part Number 48P9823 Printed in U S A 1P P N 48P9823...