5. Select
Alacritech SLIC Team Configurator
.
6. Select
New Team
.
PRO/1000 XT Server adapter
This adapter supports several teaming functions that you can configure using the
PROSet configuration utility. This adapter can also team with the integrated onboard
10/100 Intel Ethernet controller on the engine. Specific teaming modes supported
across multiple instances of this adapter are AFT, ALB, FEC/GEC, and 802.3ad.
Adding a second IBM 5191 RAID Storage Controller Model 0RU
This section gives details to follow when you have added a second RAID controller
and need to add a new logical drive or create an array in the unconfigured storage.
Attention:
Before proceeding with these steps, note the special considerations
described in “Powering off and powering on the Model 326” on page 49.
To add a second IBM 5191 RAID Storage Controller Model 0RU, you must
power-off one node, and restart the other node. It is recommended that you do the
following procedure during non-peak operation hours.
1. Install the RAID storage controller:
a. Attach a keyboard, monitor, and mouse to the node you will power-down
first.
b. Mount the RAID storage controller into a rack.
c. Attach fibre-channel cables and power cables.
d. Power-down the node (see “Powering off and powering on the Model 326”
on page 49). Make sure that you note which node you power-down in this
step.
e. Power-on the unit. Wait for all drive lights to become solid green.
f. Restart the node (see “Powering off and powering on the Model 326” on
g. On the node that is powered on, go into Storage Manager 7, right-click the
host name and select
Rescan
.
h. Once the node finds the device, it appears under the host name along with
the existing unit.
i. Right-click the new device and select
Manage
.
j. Create the new array(s) and logical drive(s) (see “Creating arrays and logical
drives” on page 32). Do not restart the node until all the arrays have finished
initializing.
k. After the array(s) have finished initializing, restart the node.
l. The node will install the new devices, and then you must start Disk
Management.
m. Create the logical partitions, format, assign drive letters and label disk(s). To
do this, use the procedure described in “Formatting the logical drives” on
page 35.
n. Power down the node, and continue with Step 2.
2. On the other node:
a. Power on the other node. It will find new devices.
b. Restart the system.
c. Upon restart, start Disk Management.
Chapter 7. Managing adapters and controllers
83
Summary of Contents for totalstorage 326
Page 8: ...viii Model 326 User s Reference...
Page 10: ...x Model 326 User s Reference...
Page 20: ...8 Model 326 User s Reference...
Page 64: ...52 Model 326 User s Reference...
Page 88: ...76 Model 326 User s Reference...
Page 134: ...122 Model 326 User s Reference...
Page 144: ...132 Model 326 User s Reference...
Page 146: ...134 Model 326 User s Reference...
Page 166: ...154 Model 326 User s Reference...
Page 182: ...170 Model 326 User s Reference...
Page 192: ...180 Model 326 User s Reference...
Page 214: ...202 Model 326 User s Reference...
Page 232: ...220 Model 326 User s Reference...
Page 238: ...226 Model 326 User s Reference...
Page 239: ......