Symptom-to-FRU Index
The Symptom-to-FRU Index lists the symptoms and errors
and the possible causes. The most likely cause is listed
first.
Note:
Perform the FRU replacement or actions in the
sequence shown in the FRU/Action columns. If a
FRU does not solve the problem, put the original
part back in the computer. Do not replace a
non-defective FRU.
This index can also be used to help you decide which
FRUs should be available when servicing a computer.
Numeric error codes show the errors detected in POST or
system operation (runtime). In the following error codes, X
can be any number.
If no codes are available, use narrative symptoms.
If the symptom, is not listed, go to “Undetermined
Problems” on page 47.
Note:
For any IBM device not supported by the diagnostic
codes in this ThinkPad computer, see the manual
for that device.
Numeric Error Codes and Messages
Error Code
Message
FRU/Action in Sequence
006
Equipment
Configuration
Error
Enter BIOS Utility and execute
″
Load Setup Default Settings
″
;
then reboot the system.
040
Diskette Drive
Controller Error
v
Go to “FRU tests” on
page 98.
v
Diskette drive connection
v
Diskette drive
v
System board
070
Real Time Clock
Error
v
Reset Time in the Basic
System Settings of BIOS
Utility.
v
Backup battery (RTC
battery)
v
Enter BIOS Utility and
execute
″
Load Setup
Default Settings
″
; then
reboot the system.
v
System board
40
ThinkPad i Series 1200/1300 HMM