(CONTINUED)
019 (continued)
Keyboard test (see “How to Run the Keyboard
Test” on page 407).
DID THE ADVANCED DIAGNOSTICS FIND AN ERROR?
Yes No
020
The problem was not detected by the diagnostics.
Check that the cables and connectors are not
damaged.
If a SCSI device is not installed, start at Step 3.
If a SCSI device is installed, do the following:
1. Check that the total number of the attached
SCSI devices is less than eight.
2. Check that the SCSI terminator is correctly
installed.
If the problems still remain, run the SCSI test.
(See “Running Diagnostics” on page 410.)
3. Reconnect all adapters, drives, and devices,
then test the system several times. A Loop
Test option is available for running all the tests.
(See “How to Run the Loop Test” on
page 407.)
After stopping the loop test, check that the error
log appears in the error list. (See “Error Log”
on page 409.)
If no errors were detected, go to “Undetermined
Problems” on page 421 and use the user
reported symptom.
If any errors are detected, go to “Numeric Error
Codes” on page 418.
021
Note the error code and go to “FRU Codes” on page 419
and replace the appropriate FRUs. If the problem remains
after all repair actions are taken, go to “Undetermined
Problems” on page 421.
396
IBM Mobile Systems HMM - Volume 1