Symptom-to-FRU Index
The symptom-to-FRU Index lists the symptoms and errors
and the possible causes. The most likely cause is listed
first.
Note: Perform the FRU replacement or actions in the
sequence shown in the “FRU/Action” columns. If a
FRU replacement did not solve the problem, put
the original part back in the computer. Do not
replace a nondefective FRU.
This index can also help you determine the next possible
FRUs to be replaced when servicing a computer.
Numeric error codes show the errors detected in POST or
system operation. In the following error codes, X can be
any number.
If no codes are available, use narrative symptoms.
If the symptom is not listed, go to “Undetermined
Problems” on page 32.
Note: For IBM devices not supported by diagnostic
codes in the ThinkPad notebook computers,
see the manual for that device.
Numeric Error Codes
Symptom / Error
FRU / Action in Sequence
10X
101: Interrupt failure.
102: Timer failure.
103: Timer interrupt
failure.
104: Protected mode
failure.
105: Last 8042
command not
accepted.
107: NMI test failure.
108: Timer bus test
failure.
109: Low meg-chip
select test.
System board
110
(Planar parity.)
1. Go to “Memory
Checkout” on
page 12.
2. DIMM
3. Detach the expansion
unit if it is attached to
the computer.
4. System board
ThinkPad 380Z
23
Summary of Contents for ThinkPad 380Z
Page 55: ...3 3 4 ThinkPad 380Z 53...
Page 70: ...When installing The following figure shows the route for the microphone and speaker cables 68...
Page 72: ...When installing The following figure shows the route for the microphone cable 70...
Page 83: ...2050 LCD Cable 2 2 2 1 Cable Bush Ferrite Core ThinkPad 380Z 81...
Page 85: ...7 When re installing Box Assembly Upper Cover Assembly ThinkPad 380Z 83...
Page 93: ...LCD Assembly 3 4 5 7 8 12 11 10 6 6b 6a 9 1 2 ThinkPad 380Z 91...
Page 103: ...ThinkPad 380Z 101...