Diagnostic
Error
Code
FRU/Action
215-000-XXX
CD-ROM
Drive
Test
Passed
1.
No
action
215-XXX-XXX
CD-ROM
Drive
error
1.
CD-ROM
Drive
Cable
2.
Check
power
supply
voltages
3.
CD-ROM
drive
4.
System
board
217-000-XXX
Hard
Disk
Drive
Test
Passed
1.
No
action
217-25X-XXX
217-26X-XXX
Hard
Disk
Drive
(IDE)
error
1.
Hard
Disk
Drive
Cable
2.
Check
power
supply
voltages
3.
Reseat
the
hard
disk
drive
cable
4.
Hard
Disk
drive
(IDE)
5.
System
board
217-28X-XXX
217-29X-XXX
Hard
Disk
Drive
(SCSI)
error
1.
Hard
Disk
Drive
Cable
2.
Check
power
supply
voltages
3.
Reseat
the
hard
disk
drive
cable
4.
Hard
Disk
drive
(SCSI)
5.
SCSI
adapter
card
6.
System
board
220-000-XXX
Hi-Capacity
Cartridge
Drive
Test
Passed
1.
No
action
220-XXX-XXX
Hi-Capacity
Cartridge
Drive
error
1.
Remove
the
Hi-Capacity
Cartridge
Drive
and
re-test
the
system
301-XXX-XXX
Keyboard
error
1.
Keyboard
2.
Check
and
test
mouse
3.
System
board
301-000-XXX
Keyboard
Test
Passed
1.
No
action
302-000-XXX
Mouse
Test
Passed
1.
No
action
302-XXX-XXX
Mouse
error
1.
Mouse
2.
Check
and
test
Keyboard
3.
System
board
303-000-XXX
Joystick
Test
Passed
1.
No
action
303-XXX-XXX
Joystick
error
1.
Remove
the
Joystick
and
re-test
the
system
305-000-XXX
Monitor
DDC
Test
Passed
1.
No
action
305-250-XXX
Monitor
DDC
self
test
failure
1.
Run
Setup
to
enable
DDC
2.
Cable
3.
Monitor
4.
Video
card
5.
System
board
68
Hardware
Maintenance
Manual
Summary of Contents for ThinkCentre 8127
Page 1: ...ThinkCentre Hardware Maintenance Manual Types 8127 8183 8184 8320 8416 8417 8418 8419 and 8429...
Page 2: ......
Page 3: ...ThinkCentre Hardware Maintenance Manual Types 8127 8183 8184 8320 8416 8417 8418 8419 and 8429...
Page 16: ...10 Hardware Maintenance Manual...
Page 24: ...18 Hardware Maintenance Manual...
Page 96: ...90 Hardware Maintenance Manual...
Page 158: ...152 Hardware Maintenance Manual...
Page 169: ...Chapter 10 Related service information 163...
Page 170: ...164 Hardware Maintenance Manual...
Page 171: ...Chapter 10 Related service information 165...
Page 172: ...166 Hardware Maintenance Manual...
Page 173: ...Chapter 10 Related service information 167...
Page 174: ...168 Hardware Maintenance Manual...
Page 175: ...Chapter 10 Related service information 169...
Page 176: ...170 Hardware Maintenance Manual...
Page 186: ...180 Hardware Maintenance Manual...
Page 187: ...Chapter 10 Related service information 181...
Page 188: ...182 Hardware Maintenance Manual...
Page 195: ......
Page 196: ...Part Number 74P2660 Printed in USA 1P P N 74P2660...