I/O expansion options

The server supports up to six PCIe slots. Slots 1 - 4 are PCIe 3.0 slots. The slots have the following slot 
form factors:

Slot 1: PCIe 3.0 x8; full-height, half-length (requires second processor)

Slot 2: PCIe 3.0 x8; full-height, full-length

Slot 3: PCIe 3.0 x8 (x4 wired); full-height, half-length 

Slot 4: PCIe 3.0 x16 (x8 wired); full-height, full-length

Slot 5: PCIe 2.0 x4 (x1 wired); full-height, half-length

Slot 6: PCIe 2.0 x8 (x4 wired); full-height, half-length (supports optional PCI-X 64 bit/133 MHz 

interposer card)

Depending on the number of processors installed and the type of power supply used, only a subset of the 
slots is available for use as listed in the following table. 

Table 13. Slot availability based on the number of processors installed and the type of power supply used

460 W fixed power 
supply

550 W hot-swap power 
supply
(1 or 2)

750 W hot-swap power 
supply
(1 or 2)

One processor 
installed

Slots 2 - 6

Slots 2 - 6

Slots 2 - 6

Two processors 
installed

Any three slots

Any three slots

All six slots

Slots 1 - 4 are PCI Express 3.0 slots. Slots 5 and 6 are PCI Express 2.0 slots. Slot 4 accepts a graphics 
processing unit (GPU) at a maximum of 75W power consumption. Slot 6 can be converted to a PCI-X slot 
(64 bit, 133 MHz) by using the kit that is listed in the following table.

Table 14. PCI riser card options

Part number

Feature
code

Description

Maximum
supported

00D4346

A2SH

PCI-X Riser Kit (for slots 6 only)

1 (slot 6 only)

Summary of Contents for System x3300 M4

Page 1: ...the latest Intel Xeon processors you can reduce costs and maintain speed and availability Suggested use for the IBM System x3300 M4 is for general business applications collaboration email web and vir...

Page 2: ...ch processor core up to two threads per core Intel Virtualization Technology integrates hardware level virtualization hooks so that operating system vendors can better use the hardware for virtualizat...

Page 3: ...sis DSA Preboot which speeds up troubleshooting tasks to reduce service time Three year customer replaceable unit and on site limited warranty 9x5 next business day Optional service upgrades are avail...

Page 4: ...into the same TDP limits Intel Intelligent Power Capability which powers individual processor elements on and off as needed to reduce power draw Low voltage Intel Xeon processors that draw less energy...

Page 5: ...figure shows the front of the server which includes the 3 5 inch drive configuration and the 2 5 inch drive configuration Figure 2 Front view of the IBM System x3300 M4 server The following figure sho...

Page 6: ...f the key components inside the server Figure 4 Inside view of the IBM System x3300 M4 server Processor 1 is installed on the system board Processor 2 is installed in on an expansion board as shown in...

Page 7: ...B with 3 TB 3 5 SATA HDDs Intermix of SAS SATA is supported but not in the same volume RAID support RAID 0 1 10 standard with the ServeRAID C105 software RAID solution Optional hardware based RAID wit...

Page 8: ...dia Security Power on password administrator s password Trusted Platform Module TPM Video Matrox G200eR2 with 16 MB memory integrated into the IMM2 Maximum resolution is 1600x1200 at 75 Hz with 16 M c...

Page 9: ...1x 4 GB H1110 4x 3 5 HS 8 Open 2x GbE 4 5 3 DVD ROM 1x 460 W fixed 1 7382 D2x 1x E5 2430 6C 2 2GHz 15MB 1333MHz 95W 1x 4 GB H1110 4x 3 5 HS 8 Open 2x GbE 4 5 3 DVD ROM 1x 550 W HS 2 7382 D4x 1x E5 24...

Page 10: ...z 10MB 1066MHz 80W 1x 4GB C105 4x 3 5 SS 8 1x 1TB 3 5 SATA SS 2x GbE 4 Multiburner 1x 460W fixed 1 Central and Eastern Europe CEE and Middle East Africa MEA 7382 E1G 1x E5 2403 4C 1 8GHz 10MB 1066MHz...

Page 11: ...z 5MB 1066MHz 80W None A3AJ None Intel Xeon Processor E5 1410 4C 2 8GHz 10MB 1333MHz 80W 00D2581 A2R4 A2RF Intel Xeon Processor E5 2403 4C 1 8GHz 10MB 1066MHz 80W A2x 00D2582 A2R5 A2RG Intel Xeon Proc...

Page 12: ...by a specific CPU Lowest maximum operating speed for the selected memory configuration which depends on the rated speed operating voltage and quantity of DIMMs per channel as shown in the Maximum ope...

Page 13: ...33 MHz 1333 MHz 1600 MHz 800 MHz 800 MHz Maximum quantity supported is shown for two processors installed When one processor is installed the maximum quantity supported is a half of what is shown The...

Page 14: ...IMM 12 B2x C2x D2x D4x F2x 49Y1407 8942 4GB 1x4GB 2Rx8 1 35V PC3L 10600 CL9 ECC DDR3 1333MHz LP RDIMM 12 49Y1397 8923 8GB 1x8GB 2Rx4 1 35V PC3L 10600 CL9 ECC DDR3 1333MHz LP RDIMM 12 49Y1400 8939 16GB...

Page 15: ...2x IBM System x3300 Simple Swap SATA Kit 4x3 5 00D2590 1x 8 Pack ServeRAID C105 Controller Enabler 90Y4349 3 4 C105 H1110 M1115 M5110 1x IBM System x3300 3 5 HS Kit for HW SW RAID 00D2591 4 3 5 LFF ho...

Page 16: ...used All Quantity 1 00D2590 A2SB IBM System x3300 Simple Swap SATA Kit 4x3 5 Used in configurations 1 and 2 in Figure 6 2 A2x 00D2591 A2SC IBM System x3300 3 5 HS Kit for HW SW RAID Used in configurat...

Page 17: ...0 SAS SATA Controller 1 C2x D2x 81Y4448 A1MZ ServeRAID M1115 SAS SATA Controller 1 D4x F2x 81Y4481 A347 ServeRAID M5110 SAS SATA Controller 1 RAID controller upgrades 81Y4542 A1X1 ServeRAID M1100 Seri...

Page 18: ...e x4 mini SAS internal connector SFF 8087 6 Gbps throughput per port Based on the LSI SAS2004 6 Gbps RAID on Chip ROC controller PCIe 2 0 x4 host interface Support for RAID 0 1 1E and 10 The ServeRAID...

Page 19: ...rom the adapter in a battery holder that is mounted inside the server case as shown in the following figure Figure 7 ServeRAID battery or flash power module installed in the battery holder For more in...

Page 20: ...M 500GB 7 2K 6Gbps NL SAS 2 5 SFF G2HS HDD 16 81Y9690 A1P3 IBM 1TB 7 2K 6Gbps NL SAS 2 5 SFF HS HDD 16 2 5 15K SAS Hot Swap HDDs 90Y8926 A2XB IBM 146GB 15K 6Gbps SAS 2 5 SFF G2HS HDD 16 90Y8944 A2ZK I...

Page 21: ...10 A22W IBM 2TB 7 2K 6Gbps NL SATA 3 5 G2SS HDD 8 81Y9814 A22V IBM 3TB 7 2K 6Gbps NL SATA 3 5 G2SS HDD 8 81Y9802 A22U IBM 500GB 7 2K 6Gbps NL SATA 3 5 G2SS HDD 8 3 5 NL SATA Simple Swap HDDs 81Y9790 A...

Page 22: ...n 5 USB Tape Drive 1 39M5636 5395 IBM DDS Generation 6 USB Tape Drive 1 43W8478 5393 IBM Half High LTO Gen 3 SAS Tape Drive 2 44E8895 5397 IBM Half High LTO Gen 4 SAS Tape Drive 2 49Y9898 5345 IBM Hal...

Page 23: ...in the table can be installed in any open 5 25 inch drive bay Figure 5 Half High SATA DVD ROM supports the following media and speeds for reading CD ROM 48X CD DA DAE 40X CD R 48X CD RW 40X DVD ROM s...

Page 24: ...nly a subset of the slots is available for use as listed in the following table Table 13 Slot availability based on the number of processors installed and the type of power supply used 460 W fixed pow...

Page 25: ...etection function MDI MDI X IEEE 1588 protocol and 802 1AS implementation IEEE802 3az Energy Efficient Ethernet EEE Full wake up support Advanced Power Management APM support Advanced Configuration an...

Page 26: ...tors IPv6 support for IP TCP and IP UDP receive checksum offload Tx TCP segmentation offload IPv4 IPv6 Transmit Segmentation Offloading TSO Interrupt throttling control Legacy and Message Signal Inter...

Page 27: ...ort CNA for IBM System x 2 3 Gigabit Ethernet 90Y9370 A2V4 Broadcom NetXtreme I Dual Port GbE Adapter for IBM System x 2 3 90Y9352 A2V3 Broadcom NetXtreme I Quad Port GbE Adapter for IBM System x 2 3...

Page 28: ...4 5 46M6049 3589 Brocade 8 Gb FC Single port HBA for IBM System x 2 3 46M6050 3591 Brocade 8 Gb FC Dual port HBA for IBM System x 2 3 Fibre Channel 4 Gb 39R6525 3567 QLogic 4 Gb FC Single Port PCIe HB...

Page 29: ...W power consumption The following table lists the supported GPUs Table 18 GPU adapters Part number Feature code Description Maximum supported 00W2299 A1QU NVIDIA Quadro 2000 1 81Y6399 A13K NVIDIA Qua...

Page 30: ...The use of the 460 W fixed power supply or 550 W power supply imposes the configuration limitations that are listed in the following table Table 20 Configuration limitations based on power supply use...

Page 31: ...including the rear fan 4 as shown in the following figure The following figure shows the location of the four fans Figure 8 Location of the cooling fans Standard fans are fan 2 and fan 4 The followin...

Page 32: ...es Intelligent Platform Management Interface IPMI Version 2 0 Simple Network Management Protocol SNMP Version 3 Common Information Model CIM Web browser The optional IMM Advanced Upgrade software feat...

Page 33: ...2008 Datacenter x86 Edition Microsoft Windows Server 2008 Datacenter x64 Edition Microsoft Windows Server 2008 Enterprise x86 Edition Microsoft Windows Server 2008 Enterprise x64 Edition Microsoft Win...

Page 34: ...m 28 2 kg 62 1 lb The x3300 M4 server has the following supported environment Server on Temperature 5 C 40 C 41 F 104 F up to 950mm 3 117ft Above 950m de rated maximum air temperature 1 C 175m Humidit...

Page 35: ...0 to 240 nominal V ac 50 60 Hz 11 3 3 A Input kilovolt amperes kVA approximately Minimum configuration 0 12 kVA Maximum 0 66 kVA Models with 750 W power supplies 100 to 127 nominal V ac 50 60 Hz 11 8...

Page 36: ...an is scheduled to arrive at the customer s location within four hours after remote problem determination is completed IBM provides service around the clock every day including IBM holidays 9x5x4 hour...

Page 37: ...CCI Class A IEC 60950 1 CB Certificate and CB Test Report Australia New Zealand AS NZS CISPR 22 2006 Class A Taiwan BSMI CNS13438 Class A CNS14336 1 China CCC GB4943 1 GB9254 2008 class A GB17625 1 20...

Page 38: ...M5120 SAS SATA Controller for IBM System x http www redbooks ibm com abstracts tips0858 html Open The ServeRAID M5120 SAS SATA Controller supports connectivity to the IBM System Storage external expan...

Page 39: ...49Y1901 600GB 15 000 rpm 6Gb SAS 3 5 HDD 12 The following table lists the hard disk drives that are supported by the EXP2524 external expansion enclosures Table 30 Drive options for EXP2524 external e...

Page 40: ...ess Dual Controller Storage System 1746A2S IBM System Storage DS3512 Express Single Controller Storage System 1746A4D IBM System Storage DS3524 Express Dual Controller Storage System 1746A4S IBM Syste...

Page 41: ...USB Enclosure Adapter Kit 40K2599 SAS Enclosure Adapter Kit Internal backup drives supported by external tape enclosures 00D2786 IBM RDX Internal USB 3 0 Dock with 320GB Cartridge 00D2787 IBM RDX Inte...

Page 42: ...6X2683 LTO Ultrium 5 SAS Drive Sled 46X2684 LTO Ultrium 5 Half High Fibre Drive Sled 46X2685 LTO Ultrium 5 Half High SAS Drive Sled 46X6912 LTO Ultrium 4 Half High Fibre Channel Drive Sled 46X7117 LTO...

Page 43: ...200 48 Port with PoE IBM System Networking 10 Gb top of rack switches 0446017 IBM System Networking RackSwitch G8124R 7309BF9 IBM System Networking RackSwitch G8124F 7309BD5 IBM System Networking Rack...

Page 44: ...53962KX IBM 1500VA LCD Tower UPS 230V Rack mounted UPS 21304RX IBM UPS 10000XHV 53951AX IBM 1500VA LCD 2U Rack UPS 100V 120V 53951KX IBM 1500VA LCD 2U Rack UPS 230V 53952AX IBM 2200VA LCD 2U Rack UPS...

Page 45: ...6M4137 IBM 0U 12 C19 12 C13 Switched and Monitored 32A 3 Phase PDU Enterprise PDUs 71762MX IBM Ultra Density Enterprise PDU C19 PDU WW 71762NX IBM Ultra Density Enterprise PDU C19 PDU WW 71763MU IBM U...

Page 46: ...ack PDU with UK LC 39Y8958 DPI Universal Rack PDU with AS NZ LC 39Y8959 DPI Universal Rack PDU with China LC 39Y8962 DPI Universal Rack PDU Argentina 39Y8960 DPI Universal Rack PDU Brazil 39Y8961 DPI...

Page 47: ...BM 42U Standard Rack 93074XX IBM 42U Standard Rack Extension 93084EX IBM 42U Enterprise Expansion Rack 93084PX IBM 42U Enterprise Rack 93604EX IBM 42U 1200 mm Deep Dynamic Expansion Rack 93604PX IBM 4...

Page 48: ...Flat Panel Console Kit Console switches 1754D2X IBM Global 4x2x32 Console Manager GCM32 1754D1X IBM Global 2x2x16 Console Manager GCM16 1754A2X IBM Local 2x16 Console Manager LCM16 1754A1X IBM Local 1...

Page 49: ...w An FMV lease can help you get the solution you need now with low monthly payments that better align upfront costs with the anticipated return on investment from the technology Acquire the solution y...

Page 50: ...ity page for the x3300 M4 http www ibm com systems info x86servers serverproven compat us xseries 7382 html IBM Redbooks Product Guides for IBM System x servers and options http www redbooks ibm com p...

Page 51: ...erials for this IBM product and use of those Web sites is at your own risk IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligati...

Page 52: ...was published Such trademarks may also be registered or common law trademarks in other countries A current list of IBM trademarks is available on the Web at http www ibm com legal copytrade shtml The...

Reviews: