ProtecTIER Service Menu running on rassmx
ProtecTIER Configuration (...)
------------------------------------------------------------------------------
1) Configure ProtecTIER node
2) Recover Configuration for a replaced server
3) Configure enclosure serial number for a replaced enclosure
4) Update Time, Date, Timezone & Timeserver(s)
5) Configure replication (...)
6) IP Network configuration (...)
7) Update Firmware
8) Update the System’s name
9) Validate configuration
10) Single node - code upgrade
B) Back
E) Exit
------------------------------------------------------------------------------
>>> Your choice?
5.
Select the
Configure ProtecTIER node
option. Type the corresponding
number and press Enter.
6.
Follow the on-screen instructions to upgrade the capacity.
7.
The begin processing procedure messages display:
Begin Processing Procedure
About to execute:
Operation:
Upgrade
Model:
TS7620_12TB
Application:
VTL
8.
Continue? (yes|no)
displays. Type
yes
and press Enter.
9.
Type
yes
and press Enter when the
Would you like to stop the VTFD
service? (yes|no)
message displays.
10.
When the configuration starts, these messages display.
Stopping services, please wait
Stopping Cluster Services
[ Done ]
Services stopped
Checking installed applications
[ Done ]
Checking conditions...
Checking BOM
[ Done ]
Disable MegaRAID Bios
[ Done ]
Disable MegaRAID PD Fail History
[ Done ]
Checking for existing nodes
[ Done ]
Checking NICs for Replication
[ Done ]
Checking repository
[ Done ]
Checking installed applications
[ Done ]
Checking conditions done
Starting cluster
[ Done ]
Starting VTFD
[ Done ]
Starting RAS
[ Done ]
Upgrading Repository
[ Done ]
Stopping RAS
[ Done ]
Stopping VTFD
[ Done ]
Starting VTFD
[ Done ]
Starting RAS
[ Done ]
Collecting RAS Persistent configuration
[ Done ]
Running RAS Eth Agent
[ Done ]
validation will start in 10 seconds
Testing customer network connectivity
[ Done ]
Testing connectivity to the Default Gateway
[ Done ]
Getting number of nodes
[ Done ]
This is a 1 node cluster, will not test fencing
validation ended
Chapter 4. Increasing capacity
27
|
|
|
|
|
|
|
|
Summary of Contents for System Storage ProtecTIER TS7620
Page 4: ...iv Increasing Capacity on the 3959 SM2 Feature Code 9317 ...
Page 44: ...40 Increasing Capacity on the 3959 SM2 Feature Code 9317 ...
Page 52: ...48 Increasing Capacity on the 3959 SM2 Feature Code 9317 ...
Page 54: ...50 Increasing Capacity on the 3959 SM2 Feature Code 9317 ...
Page 57: ......
Page 58: ... Part Number 39U3474 Printed in USA GA32 2222 03 1P P N 39U3474 ...