Note: There is no power-on switch on the EXP2500 or on the power
supplies. A power supply is active when a power cord is connected to it and
to a power source.
The EXP2500 might take a few seconds to power-on. During this time, you might
see the EXP2500 amber fault LED, green power LED, power supply LEDs, and
blue system locator LED turn on and off intermittently. When the power-on
sequence is completed, only the green power LEDs on the front and rear should
remain lit. If one or more amber fault LEDs remain lit, see Chapter 5, “Solving
problems,” on page 41.
Powering off the EXP2500
Attention:
Except in an emergency situation, never power-off if any fault LEDs
are lit on the EXP2500. Correct the fault before you attempt to power-off the
enclosure, using the correct troubleshooting or servicing procedure. For more
information, see Chapter 5, “Solving problems,” on page 41.
DANGER
Multiple power cords. The product might be equipped with multiple power
cords. To remove all hazardous voltages, disconnect all power cords.
(L003)
1
2
or
!
1
2
22
System Storage EXP2512 and EXP2524: Installation and Maintenance Guide
Summary of Contents for System Storage EXP2512 Express Storage Enclosure
Page 2: ......
Page 10: ...viii System Storage EXP2512 and EXP2524 Installation and Maintenance Guide ...
Page 28: ...16 System Storage EXP2512 and EXP2524 Installation and Maintenance Guide ...
Page 56: ...44 System Storage EXP2512 and EXP2524 Installation and Maintenance Guide ...
Page 66: ...54 System Storage EXP2512 and EXP2524 Installation and Maintenance Guide ...
Page 70: ...58 System Storage EXP2512 and EXP2524 Installation and Maintenance Guide ...
Page 71: ......
Page 72: ... Part Number 90Y8809 Printed in USA GA32 0965 01 1P P N 90Y8809 ...