Table 16. Battery unit LEDs
LED
Normal Status
Problem Status
Service Action
Allowed (OK to
Remove)
Off
On
Service Action
Required (Fault)
Off
On
Battery Charging
Green means on,
ready
Flashing green means
charging
Off
The Global Power, Global Summary Fault, and Global Locate LEDs are general
indicators for the entire DS5020 storage subsystem (or configuration, in the case of
the Global Summary Fault). The Global Summary Fault LED turns on if a fault
condition is detected in any component in the storage subsystem configuration,
including all attached storage expansion enclosures. The Global Power, Global
Summary Fault, and Global Locate LEDs shine through the front bezel.
Attention:
If the Global Summary Fault LED lights, refer to the DS Storage
Manager client software to determine the problem with the storage subsystem. Also,
inspect the Needs Attention LEDs on the other components in the storage
subsystem to help isolate the fault to a specific component.
Controller LEDs
This section describes the primary LEDs, controls, and connectors on the rear of
the storage subsystem controller.
Figure 69 on page 107, Figure 70 on page 107, and Figure 71 on page 108 show
the three different DS5020 controller configurations that are available. Figure 69 on
page 107 shows the base DS5020 storage subsystem, with two Fibre Channel host
ports. For more information about DS5020 controller options and other components,
see the “Parts listing” on page 166.
Service action
allowed (ok to
remove) LED
Service action
required
(fault) LED
Battery
charging
LED
Service action
allowed (ok to
remove) LED
Service action
required
(fault) LED
Battery
charging
LED
Figure 68. Battery unit LEDs
106
IBM System Storage DS5020 Storage Subsystem: Installation, User’s, and Maintenance Guide
Summary of Contents for System Storage DS5020
Page 2: ......
Page 9: ...Glossary 213 Index 223 Contents vii...
Page 10: ...viii IBM System Storage DS5020 Storage Subsystem Installation User s and Maintenance Guide...
Page 14: ...xii IBM System Storage DS5020 Storage Subsystem Installation User s and Maintenance Guide...
Page 30: ...xxviii IBM System Storage DS5020 Storage Subsystem Installation User s and Maintenance Guide...
Page 58: ...28 IBM System Storage DS5020 Storage Subsystem Installation User s and Maintenance Guide...
Page 152: ...122 IBM System Storage DS5020 Storage Subsystem Installation User s and Maintenance Guide...
Page 186: ...156 IBM System Storage DS5020 Storage Subsystem Installation User s and Maintenance Guide...
Page 208: ...178 IBM System Storage DS5020 Storage Subsystem Installation User s and Maintenance Guide...
Page 216: ...186 IBM System Storage DS5020 Storage Subsystem Installation User s and Maintenance Guide...
Page 220: ...190 IBM System Storage DS5020 Storage Subsystem Installation User s and Maintenance Guide...
Page 232: ...202 IBM System Storage DS5020 Storage Subsystem Installation User s and Maintenance Guide...
Page 252: ...222 IBM System Storage DS5020 Storage Subsystem Installation User s and Maintenance Guide...
Page 258: ...228 IBM System Storage DS5020 Storage Subsystem Installation User s and Maintenance Guide...
Page 259: ......
Page 260: ...Part Number 00Y5047 Printed in USA GA32 0954 03 1P P N 00Y5047...