Enclosure loss protection is not valid when you create logical drives on existing subsystems.
The
drawerLossProtect
parameter defines if data on a logical drive is accessible if a drawer fails. When
you assign the drives, if you set the
drawerLossProtect
parameter to
TRUE
and select more than one drive
from any one drawer, the storage subsystem returns an error. If you set the
drawerLossProtect
parameter
to
FALSE
, the storage subsystem performs operations, but the subsystem that you create might not have
drawer loss protection.
You must set the
enclosureLossProtect
parameter and the
drawerLossProtect
parameter to the same
value. Both of the parameters must be either
TRUE
or
FALSE
. If the
enclosureLossProtect
parameter and
the
drawerLossProtect
parameter are set to different values, the storage subsystem returns an error.
Security Type
See “Security Type” on page 4-34 for an explanation of this new parameter.
Related Topic
Create RAID Logical Drive (Free Extent Based Select)
This command creates a logical drive in the free space of an subsystem.
Syntax
create logicalDrive subsystem="
subsystemNumber
"
userLabel=”
logicalDriveName
”
[freeCapacityArea=
freeCapacityIndexNumber
capacity=
logicalDriveCapacity
owner=(a | b)
cacheReadPrefetch=(TRUE | FALSE)
segmentSize=
segmentSizeValue
usageHint=(fileSystem | dataBase | multiMedia)
[dssPreAllocate=(TRUE | FALSE)
securityType=(none | capable | enabled)
T10PI=(none | enabled)]
Parameters
Parameter
Description
subsystem
The alphanumeric identifier (including - and _) for a
specific subsystem in your storage subsystem.
userLabel
The name that you want to give the new logical drive.
Enclose the new logical drive name in double quotation
marks (“ ”).
3-90
IBM System Storage DS3000, DS4000, and DS5000: Command Line Interface and Script Commands Programming Guide
Summary of Contents for System Storage DS3000
Page 599: ...Appendix A Examples of information returned by the show commands A 3...
Page 601: ...Appendix A Examples of information returned by the show commands A 5...
Page 603: ...Appendix A Examples of information returned by the show commands A 7...
Page 605: ...Appendix A Examples of information returned by the show commands A 9...
Page 607: ...Appendix A Examples of information returned by the show commands A 11...
Page 609: ...Appendix A Examples of information returned by the show commands A 13...
Page 611: ...Appendix A Examples of information returned by the show commands A 15...
Page 623: ...Appendix A Examples of information returned by the show commands A 27...
Page 625: ...Appendix A Examples of information returned by the show commands A 29...
Page 627: ...Appendix A Examples of information returned by the show commands A 31...
Page 651: ......
Page 652: ...Part Number 00W1466 Printed in USA GA32 0961 05 1P P N 00W1466...