MAP 0150: Intermittent Problem Isolation
001
– Make sure that:
All cables are attached correctly.
The room temperature is not outside the limits [5° to 41°C (50° to 104°F)].
Did you find a problem?
Yes No
002
Continue with Step 004.
003
Resolve the problem. Then, go to “MAP 0210: Verify Operation” on page 2-23.
004
Is the fan running?
Yes No
005
Are any of the LEDs on? Check the LEDs on both sides of the IBM
2210.
Yes No
006
Make sure that:
The IBM 2210 is plugged into the wall outlet.
The wall outlet has the correct voltage.
The line voltage at the end of the power cord is correct.
Did you find a problem?
Yes No
007
Replace the power supply. Then, go to “MAP 0210: Verify
Operation” on page 2-23.
008
Correct the problem. Then, go to “MAP 0210: Verify Operation” on
page 2-23.
009
(Step 009 continues)
Chapter 2. Problem Determination
2-11
Summary of Contents for SY27-0345-06
Page 1: ...2210 Nways Multiprotocol Router Service and Maintenance Guide SY27 0345 06...
Page 2: ......
Page 3: ...IBM 2210 Nways Multiprotocol Router Service and Maintenance Guide SY27 0345 06...
Page 6: ...UL Notices D 13 Trademarks D 13 Glossary X 1 Index X 9 iv 2210 Service and Maintenance...
Page 22: ...1 8 2210 Service and Maintenance...
Page 46: ...2 24 2210 Service and Maintenance...
Page 94: ...4 44 2210 Service and Maintenance...
Page 104: ...B 2 2210 Service and Maintenance...
Page 117: ...Appendix C Parts Listing C 13...
Page 120: ...C 16 2210 Service and Maintenance...
Page 132: ...D 12 2210 Service and Maintenance...
Page 134: ...D 14 2210 Service and Maintenance...
Page 142: ...X 8 2210 Service and Maintenance...
Page 147: ......
Page 148: ...IBM Part Number 30L6566 Printed in U S A 3 L6566 SY27 345 6...