3-6
ServeRAID-MR10is SAS/SATA Controller Characteristics
3.3.3
Fault Tolerance
shows the fault tolerance features of the ServeRAID-MR10is
controller.
3.3.4
Electrical Characteristics
All power is supplied to the ServeRAID-MR10is controller through the
PCI Express 3.3V rails and the 12V rail. Onboard switching regulator
circuitry operating from the 3.3V rails and the 12V rail provide the
necessary voltages. The following states determine the typical current
consumption of the controller:
•
State 1: During a hard reset
•
State 2: During a disk stress test
Stripe Sizes
8, 16, 32, 64, 128, 256, 512, and 1024
Kbytes
Maximum Number of Concurrent
Commands
255
Support for Multiple Initiators
Yes
Table 3.4
Array Performance Features (Cont.)
Specification
ServeRAID-MR10is Controller
Table 3.5
Fault Tolerance Features
Specification
ServeRAID-MR10is Controller
Support for SMART
1
1.
The Self Monitoring Analysis and Reporting Technology (SMART) detects
up to 70 percent of all predictable disk drive failures. In addition, SMART
monitors the internal performance of all motors, heads, and drive
electronics.
Yes
Optional Battery Backup for
Cache Memory
iBBU battery backup. 4.8V/880mAH battery
pack; up to 72 hours of data retention for
512 Mbytes
Drive Failure Detection
Automatic
Drive Rebuild Using Hot Spares Automatic
Parity Generation and Checking Yes
Summary of Contents for ServeRAID-MR10is
Page 12: ...xii Contents...
Page 14: ...xiv Contents...
Page 16: ...xvi Contents...
Page 34: ...1 18 Overview...
Page 56: ...3 12 ServeRAID MR10is SAS SATA Controller Characteristics...
Page 86: ...A 4 Notices...
Page 92: ...B 6 Glossary of Terms and Abbreviations...
Page 93: ......
Page 94: ...4 6 M1 3 7 8...