Connecting the ServeRAID-MR10is iBBU Remotely
5-5
Step 1. With the controller on a flat, clean, static-free surface, ground
yourself, and remove the daughtercard, standoff, and screws
from the package.
Step 2. Place the standoff on the controller so that the bottom side is
over the screwhole next to the J1 connector on the controller.
Step 3. Use one of the screws to secure the standoff to the controller.
Important:
Center the screwdriver carefully to avoid stripping the
screwhead. Do not over-tighten the screws.
Step 4. Hold the daughtercard so that the J2 board-to-board connector
on the daughtercard lines up with the J1 board-to-board
connector on the controller.
Step 5. Carefully press the J2 connector on the daughtercard into the
J1 connector on the controller so that the two connectors are
firmly joined.
The connectors fit only when they are in the correct alignment.
Step 6. Use the other screw to secure the daughtercard to the
controller and continue with the next procedure.
Figure 5.3
Connecting the Daughtercard to the ServeRAID-MR10is
SAS/SATA Controller