Installing device drivers
19
f.
Record the slot number for the ServeRAID controller; then, press Esc three
times to return to the controller-selection screen.
g.
Repeat step c on page 18 through step 3f until you record the slot number for
each ServeRAID controller that appears on the selection screen.
4.
Turn off the server; then, remove all ServeRAID, IDE, and SCSI disk-storage
adapters and controllers except the one attached to the drive where you intend to
install UnixWare.
Note: If one of the disk-storage or ServeRAID controllers that you need to
remove is on the system board, do one of the following:
•
If the CD-ROM drive that you are using to install your operating sys-
tem is attached to the integrated controller, disconnect or remove all
disk drives attached to the integrated controller.
•
If only disk drives are attached to the integrated controller, disconnect
the SCSI or IDE cable for the integrated controller from the connector
on the system board. See the label inside the server cover for the
location of the SCSI and IDE cable connectors.
5.
Follow the instructions in “Installing the device drivers while installing UnixWare”;
then, return here and continue with step 6.
6.
Turn off the server.
7.
Install any non-ServeRAID disk-storage adapters or controllers in the server;
then, attach the drives to the disk-storage adapters and controllers.
8.
Install the first ServeRAID controller from the list you created in step f.; then,
attach the drives to the ServeRAID controller.
9.
Turn on the server and allow UnixWare to detect the new disk-storage adapters
and controllers.
10. Turn off the server.
11. Repeat step 8. through 10. until all ServeRAID adapters, ServeRAID controllers,
and drives are installed.
12. You can now partition and format the logical drives attached to the ServeRAID
adapters and controllers. See the information provided with UnixWare for more
instructions.
Installing the device drivers while installing UnixWare
To install the ServeRAID device drivers while installing UnixWare 7.1:
1.
Use the instructions provided with UnixWare to begin the installation.
2.
When a message appears asking if you want to install any HBA diskettes, insert
the
IBM ServeRAID Device Drivers for SCO Operating Systems - UnixWare HBA
and OpenServer BTLD
diskette; then, select Install HBA diskette.
3.
Use the instructions provided in the UnixWare manual to complete the normal
installation process.
Installing or updating device drivers after installing UnixWare
Use the following instructions to install the ServeRAID files after you install UnixWare,
or use these instructions to update a previously installed ServeRAID file with a newer
version. You can use the UnixWare Pkgadd or the UnixWare SCOAdmin utility pro-