One IM or IME volume and IS volume per blade server

z

Two IS volumes per blade server

z

Each blade with an SAS expansion card has access to its assigned HDDs in both DSMs, even if only 

z

one SAS Connectivity module is present. Potentially, all 12 drives in both DSMs can be assigned to 
the single blade server. However, only 10 HDDs can be used in a single volume. You can create 
either two volumes to utilize the capacity of all drives, or designate the remaining two drives as hot 
spares.

Both SAS and SATA hot swap HDDs are supported, and intermix of SAS/SATA drives is supported 

z

as well. However, each volume must have hard disks of the same type, that is, SAS or SATA.

External disk storage attachments are not supported.

z

BladeCenter S integrated storage  - advanced RAID functionality with shared storage

The configuration shown in Figure 5 connects the SAS Connectivity Card (CIOv) installed in each blade 

server to the integrated BladeCenter S storage using two IBM BladeCenter S SAS RAID Controller 
Modules in the BladeCenter S chassis. In this configuration, the RAID functionality is provided by the 
RAID Controller Modules in the BladeCenter chassis (and not by the RAID controller that is on the blade 
server's system planar).

Figure 5. IBM BladeCenter S with advanced RAID functionality

The parts used in this configuration are listed in Table 6.

Summary of Contents for SAS Connectivity Card (CIOv)

Page 1: ...Connectivity Card CIOv is shown in Figure 1 Figure 1 SAS Connectivity Card CIOv for IBM BladeCenter Did you know The adapter is based on the PCI Express bus which can be thought of as a high speed se...

Page 2: ...AS ports of blade server s onboard LSI 1064e disk z storage controller Support for two full duplex SAS ports at 3 Gbps maximum per channel z Support for SAS SSP and SMP protocols z Operating environme...

Page 3: ...er HS22 The SAS Connectivity Card CIOv requires that a supported I O module is installed in bay 3 and bay 4 depending on the configuration of the chassis in which the cards and servers are installed T...

Page 4: ...s used in this configuration are listed in Table 4 Table 4 Components used when connecting the SAS Connectivity Card CIOv to external disk storage Diagram reference Part number Machine type Descriptio...

Page 5: ...Partition Expansion License is z required to support more than four host server blades RAID levels 0 1 10 3 5 and 6 are supported by DS3200 z A maximum of 48 drives is supported in a single RAID 0 1 a...

Page 6: ...storage partitions and so forth as in shared storage systems Instead each blade has its own set of physical disks residing in DSM or DSMs The SAS Connectivity Module controls disk assignments by using...

Page 7: ...SAS SATA drives is supported z as well However each volume must have hard disks of the same type that is SAS or SATA External disk storage attachments are not supported z BladeCenter S integrated sto...

Page 8: ...s or be shared by several blade servers Zoning is supported by the SAS RAID controller module However zoning should not be used for z regular operations that is for purposes other than troubleshooting...

Page 9: ...Edition z Red Hat Enterprise Linux 5 Server Edition z SUSE Linux Enterprise Server 10 for x86 z SUSE Linux Enterprise Server 10 with Xen for AMD64 EM64T z SUSE Linux Enterprise Server 10 with Xen for...

Page 10: ...rt of the materials for this IBM product and use of those Web sites is at your own risk IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring...

Page 11: ...gistered or common law trademarks in other countries A current list of IBM trademarks is available on the Web at http www ibm com legal copytrade shtml The following terms are trademarks of the Intern...

Reviews: