For example, to write the machine serial number to the system board when the serial number is
“13-FEDCB” and the node name is “ZYXW3,” you would issue the following command:
writesernum –sernum
13FEDCB ZYXW3
Note:
The node will restart as soon as the serial number has been written to it.
Replacing the SAN Volume Controller 2145-8A4 system board
All the components that were removed when you removed the system board are reused during the
installation of the new system board.
Ensure that you have a monitor and USB keyboard available because they are required during this
procedure. You also need a power cable so that you can turn on the node while it is out of the rack.
Note:
When you reassemble the components in the server, be sure to route all cables carefully so that
they are not exposed to excessive pressure.
Perform the following steps to install the system board:
1.
Align the system board with the chassis, and replace the eight screws that you removed
2.
Orient the microprocessor retention module as shown in Figure 292.
Attention:
In the following step, do not overtighten the screws or touch the system board with the
screwdriver. Tighten the screws only until they are snug, and then tighten them an additional
quarter turn.
3.
Replace the microprocessor retention module. Gently secure it with the four screws that you
removed.
svc00492
Figure 292. The SAN Volume Controller 2145-8A4 microprocessor bracket frame fully opened
Chapter 2. Removing and replacing parts
291
Summary of Contents for SAN Volume Controller 2145-CG8
Page 1: ...System Storage SAN Volume Controller Hardware Maintenance Guide Version 6 2 0 GC27 2283 00...
Page 2: ......
Page 3: ...System Storage SAN Volume Controller Hardware Maintenance Guide Version 6 2 0 GC27 2283 00...
Page 14: ...xii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 24: ...xxii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 30: ...xxviii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 54: ...24 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 362: ...332 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 364: ...334 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 371: ......
Page 372: ...Part Number 31P1584 Printed in USA GC27 2283 00 1P P N 31P1584...