5.
Place the cable on the table.
Replacing the disk and fan signal cable in the 8335-GTB system
Follow these steps to replace a disk and fan signal cable in the IBM Power System S822LC (8335-GTB)
system.
Procedure
1.
Ensure that you have the electrostatic discharge (ESD) wrist strap attached. If not, attach it now.
2.
Using the labels, connect the disk and fan signal cable (A) to the disk drive and fan card (B) and to
the system backplane (C). Ensure that the cable latch clip snaps into place on the connectors. See
Figure 56 on page 46.
Figure 55. Removing the disk and fan signal cable
Removing and replacing parts in the IBM Power System S822LC (8335-GTB)